OPERATION
Version 03/2008
WATERCLEAN 1600
- 56 -
3.4.1.5
UV Treatment (Option)
1.
Switch on the UV irradiator with the switch (39/1); the LEDs (39/2,
3, 4) flash briefly.
2.
During the switching-on phase (1 to 2 minutes) the LEDs light up
in the sequence red (39/2), yellow (39/3), and green (52/4).
3.
After the switching-on phase, the green LED "Function o.k." (39/4)
illuminates; the UV treatment is active.
Fig. 39
Operating elements, UV switch cabinet
In case of decreasing UV irradiation intensity (<75 %), the yellow "Pre-
alarm" LED (39/3) illuminates. If the UV irradiation intensity sinks be-
low 50 %, the red "Main alarm" LED (39/2) illuminates. The irradiator
must be replaced then, according to Section 4.3.3.
3.4.2
Automatic Operation (Standard Operating Mode)
Before switching on make sure
that
:
• the levers and the hand wheel
of the Double Pass control
panel are in position
I
"Single
Pass" (option)
• the valves V10, V12 and V15
are shut
• the starting position of the con-
centrate return (V05)
- open for untreated water
< 10 000 ppm salt content
- shut for untreated water
> 10 000 ppm salt content.
NOTE
In Fig. 40, valve V05 points in the direction of flow
and is thus open.
1
2
6
4
3
5
Fig. 40
Valve V05 open
1
Содержание WATERCLEAN 1600
Страница 2: ......
Страница 14: ...GENERAL Version 03 2008 WATERCLEAN 1600 8 ...
Страница 28: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 22 Fig 13 Anti scalant mounting kit 1 2 ...
Страница 48: ...DESCRIPTION Version 03 2008 WATERCLEAN 1600 42 ...
Страница 82: ...OPERATION Version 03 2008 WATERCLEAN 1600 76 ...
Страница 106: ...APPENDIX Version 03 2008 WATERCLEAN 1600 100 ...
Страница 108: ......
Страница 110: ......