– 6
Illustrations on Page 2
Illustration
Insert the descaler cartridge into the opening and
push it until it is tightly fitted.
Illustration
Fill the water tank with a maximum of 1 litre of fresh
tap water.
Illustration
Plug in the mains plug.
Press the ON switch to turn on the appliance.
Illustration
Indicator lamp glows green.
The device is ready for use after approx. 30 sec-
onds.
Illustration
Set water hardness prior to first use.
ATTENTION
In order to guarantee the optimum functionality of the
descaler cartridge, the device must be set to the local
water hardness prior to the first operation.
Further information concerning the device setting can
be found in Chapter "Effect descaler cartridge and set-
ting of water hardness".
Illustration
Connect the accessories to the steam gun.
Operate steam lever.
ATTENTION
Only work with a cartridge inserted.
As soon as the device is filled with water and is tak-
en into operation, the descaling effect of the car-
tridge is activated.
Lime that is contained in the water is absorbed by
the granules in the cartridge. This prevents the cal-
cification of the device. An additional device desca-
ling is thus not required.
Note
The granules in the cartridge can change their colour af-
ter contact with water; this is related to the mineral con-
tent in the water. This discolouration is harmless and
does not have any negative effects on the device, clean-
ing work or the functionality of the cartridge.
Note
The hardness of the tap water can be inquired at your
water management office or the municipal utilities.
ATTENTION
In order to guarantee the optimum functionality of the
descaler cartridge, the device must be set to the local
water hardness prior to the first operation.
This is done via the RESET button.
Notes
The device is set to the highest water hardness lev-
el (level IV) by default.
After completion of the water hardness setting, it
remains saved until a new setting (e.g. after reloca-
tion) is necessary.
During the setting no pause of more than 15 sec-
onds may take place. Otherwise the device is auto-
matically set to the water hardness selected last or
the highest water hardness with initial start-up.
Please observe the following procedure:
Connect the mains cable to the power supply sys-
tem.
The device must be switched off prior to the setting.
Push the RESET button and hold it down during the
start-up of the device.
After 2 seconds the indicator light is blinking and
signals the current setting of the water hardness via
the number of impulses.
By repeatedly pressing the RESET button, the set-
ting of the water hardness level changes.
As long as the RESET button is pressed, the flash-
ing impulse for the relevant water hardness level is
not shown.
As soon as the button is released, the flashing im-
pulse appears for the output of the selected water
hardness.
If the water hardness is set to the desired level,
hold down the RESET button for 3 seconds so that
the setting is saved.
The saving process is displayed by the lighting up
of the indicator light for the water hardness.
ATTENTION
If the device is used in another area with a different wa-
ter hardness (e.g. after relocation), the water hardness
must be reset.
E1
Extension tubes (two tubes)
E2
Unlocking button
F1
Floor nozzle
F2
Retaining clip
F3
Terry floor cloth
F4
Microfibre floor cloth
Quick Reference
Effect descaler and adjustment of water
hardness
Effect descaler cartridge
Water hardness levels and flashing impulses
Degree of hard-
ness
° dH mmol/l Number
of flashing
impulses
Interval of
flashing
impulses
I soft
0- 7
0-1,3
1x
4 seconds
II medium
7-14 1,3-2,5
2x
III hard
14-21 2,5-3,8
3x
IV very hard
>21
>3,8
4x
Setting of the water hardness
12
EN