background image

12 

English

Suited for all washable walls and floor cov-
erings, e.g. stone floors, tiles and PVC 
floors. Work slowly on very dirty surfaces to 
allow the steam to act on the dirt for a long-
er period of time.

Note: 

Detergent residue or care emulsions 

that are still present on the surfaces to be 
cleaned, can lead to smears when steam 
cleaned. However, these will disappear 
with repeated cleaning procedures.

Illustration 
Attach the floor cloth to the floor nozzle.

1 Fold the floor cloth the long way and 

place the floor nozzle on top of it.

2 Open holding clamps.
3 Place the cloth ends into the openings.
4 Close the holding clamps.

Caution

Do not insert fingers between the clamps.

Illustration 
During work breaks, hook the floor noz-
zle into the parking holder.

Danger

Always disconnect the mains plug and al-
low the steam cleaner to cool down before 
performing any maintenance work.

Rinse the steam cleaner boiler at the latest 
after 10 boiler fillings.

Fill the boiler with water and shake it 
strongly. This dissolves lime scaling re-
siding on the boiler bottom. 

Empty water out.

Note: 

If you always use usual commercial 

distilled water it is not necessary to descale 
the boiler.

As limescale builds up on the boiler walls, 
we recommend to descale the boiler in the 
following intervals (RF=reservoir fillings):

Note:

 Please contact your Conservancy 

Board or the local water supply company to 
inquire about the hardness of your water.

Disconnect the mains plug from the 
socket.

Allow device to cool down.

Remove the safety cap from the device.

Completely empty the steam boiler to 
remove existing water (see fig.  ).

Warning

Only use products approved by KÄRCHER 
to exclude any damages of the appliance.

User the KÄRCHER decalcifier sticks 
(order no. 6.295-206) to decalcify the 
water. Please follow the dosing instruc-
tions on the packaging while using the 
decalcifying solution.

Floor nozzle

Parking the floor nozzle

Maintenance and care

Rinsing the boiler

Descaling the boiler

Degree of hardness ° dH

mmol/l RF

I

soft

0- 7 

0-1,3

55

II medium

7-14

1,3-2,5 45

III hard

14-21 2,5-3,8 35

IV very hard

>21

>3,8

25

Содержание SC 3.000

Страница 1: ...Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them 59636730 04 13 SC 3 000...

Страница 2: ...ormation 3 Safety instructions 4 Description of the Appliance 6 Quick Reference 7 Operation 8 How to Use the Accessories 11 Maintenance and care 12 Troubleshooting 13 Customer Service 14 Technical spe...

Страница 3: ...r damage to property Steam CAUTION Danger of scalding The packaging material can be recy cled Please do not place the packag ing into the ordinary refuse for disposal but arrange for the proper recycl...

Страница 4: ...upply which has been installed in accordance with IEC 60364 The appliance may only be connected to alternating current The voltage must correspond with the type plate on the appliance In wet rooms e g...

Страница 5: ...re controller keeps the boiler pressure during the operation as constant as possible The heating is turned off if the maximum operating pressure of 4 bar is reached in the boiler and is reactivated in...

Страница 6: ...holder for floor nozzle A8 Mains cable with mains plug A9 Running wheels 2 ea A10Steering roller B1 Steam gun B2 Unlocking button B3 Selector switch for the steam volume with child protection B4 Steam...

Страница 7: ...of 1 litre of water 2 Screw in safety cap 3 Plug in the main plug Turn on the appliance The green and orange indicator lamps light up 4 Wait until the orange indicator lamp goes out 5 Connect the acce...

Страница 8: ...8 English Operation...

Страница 9: ...ters of fresh tap water Note You can cut down the heating up time by using warm water Screw the safety cap back onto the de vice Place the unit securely on a firm sur face Caution The appliance must n...

Страница 10: ...he water may splash back during the filling process Do not fill any detergents or other additives into the boiler Screw the safety cap back onto the de vice Insert the mains plug into a socket Press t...

Страница 11: ...t steam onto the sealed loca tions of the window frame to prevent dam age You can use the steam gun without any ad ditional accessories e g to remove odours and wrinkles from hanging clothes by steami...

Страница 12: ...lings Fill the boiler with water and shake it strongly This dissolves lime scaling re siding on the boiler bottom Empty water out Note If you always use usual commercial distilled water it is not nece...

Страница 13: ...softener as this would affect the ability of the cloths to pick up dirt You may tumble dry the cloths Often failures have simple causes and you can do the troubleshooting yourself using the following...

Страница 14: ...by faulty material or defects in man ufacturing In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service centre Please submit the proof of purchase Subjec...

Страница 15: ...English 15 Spare Parts...

Страница 16: ...www karcher co nz www karcher com au...

Отзывы: