NT 801 B1
14
English
4. Trouble-shooting
With the help of the following information you should be able to resolve any problems that might occur
yourself.
Motor (suction turbine)
does not start
No voltage
Check fuse, plug, and socket
Rotary switch is incorrectly set
Change over
Dust is escaping during
the suction process
Cartridge filter not correctly
fitted or defective
Check filter seat or replace
Filter indicator lights up
Filter bag full or cartridge filter
clogged
Switch off cleaner, replace filter
bag or change cartridge filter.
Suction force is gradually
decreasing
Cartridge filter, nozzle, suction
hose or suction pipe blocked
Check, clean accessories, change
filter bag or replace cartridge filter
Malfunction
Cause
Remedy
All testing and work on electrical components should be carried out by a qualified electrician. In the case
of more serious problems, please contact KÄRCHER Customer Service.