– 11
You can rectify minor faults yourself
with the help of the following overview.
If in doubt, please consult the author-
ized customer service.
Danger
Turn off the appliance and re-
move the mains plug prior to any
care and maintenance work.
Repair works may only be per-
formed by the authorized cus-
tomer service.
Pull on the lever of the trigger gun;
the device will switch on.
Check whether the voltage indicat-
ed on the type plate corresponds to
the voltage of the mains supply.
Check the mains connection cable
for damages.
Check setting at the spray lance.
Appliance ventilation: Switch the
appliance on with the high-pressure
hose detached and operate (max. 2
minutes) until the water exits the
high-pressure connection without
bubbles. Switch off appliance and
reconnect high-pressure hose.
Check the water supply.
Pull out the sieve in the water con-
nection using flat-nose pliers and
clean under running water.
Voltage reduction due to weak mains
supply or when using an extension cable.
When switching on, first pull the lever
of the trigger gun and then switch the
appliance switch to "I/ON".
Clean high-pressure nozzle: Re-
move dirt and debris from the noz-
zle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
Slight leakage from the appliance
pump is normal. If the leakage in-
creases contact the authorized cus-
tomer service.
Use spray lance with pressure reg-
ulation (Vario Power).
Turn the spray lance to "Mix" posi-
tion.
Clean the detergent suction hose
filter.
Check the detergent suction hose
for kinks.
Troubleshooting
Appliance is not running
Pressure does not build up in
the appliance
Appliance does not start,
motor hums
Strong pressure fluctuations
Appliance is leaking
No detergent infeed
Technical specifications
Electrical connection
Voltage
230
1~50
V
Hz
Connected load
2,5 kW
Protection class
IP X5
Protective class
I
Mains fuse (slow-blow)
16 A
Water connection
Max. feed pressure
0,6 MPa
Max. feed temperature
60 °C
Min. feed volume
11 I/min
Max. Suction height
1,0 m
Performance data
Working pressure
13 MPa
Max. permissible pressure
15 MPa
Water flow rate
8,8 I/min
Detergent flow rate
0,3 I/min
Recoil force of trigger gun
20 N
22
EN