manualshive.com logo in svg
background image

     - 

m

Danger

Turn off the appliance and remove the mains 
plug prior to any care and maintenance work.

The appliance is maintenance-free.

Prior to longer periods of storage, e.g. in the win-
ter:

 

Completely drain all water from the appli-
ance: Switch the appliance on with detached 
high-pressure hose and detached water sup-
ply (max. 1 minute) and wait, until no more 
water exits at the high-pressure connection. 
Turn off the appliance.

 

Remove filter from suction hose for deter-
gent and clean under running water.

 

Pull out the sieve in the water connection us-
ing flat-nose pliers and clean under running 
water.

Caution

Protect the appliance and its accessories against 
frost.

The appliance and its accessories can get de-
stroyed through frost if there are any water resi-
dues in them. To avoid damage to them:

 

Store the appliance and the entire accesso-
ries in a frost-safe room.

Use only original KÄRCHER spare parts. You 
will find a list of spare parts at the end of these 
operating instructions.

You can rectify minor faults yourself with the help 
of the following overview. 
If in doubt, please consult the authorized cus-
tomer service.

m

Danger

Turn off the appliance and remove the mains 
plug prior to any care and maintenance work.
Repair works may only be performed by the au-
thorized customer service.

 

Pull on the lever of the trigger gun; the device 
will switch on.

 

Check whether the voltage indicated on the 
type plate corresponds to the voltage of the 
mains supply.

 

Check the mains connection cable for dam-
ages.

 

Appliance ventilation: Switch the appliance 
on with the high-pressure hose detached 
and operate (max. 2 minutes) until the water 
exits the high-pressure connection without 
bubbles. Switch off appliance and reconnect 
high-pressure hose.

 

Check the water supply.

 

Pull out the sieve in the water connection us-
ing flat-nose pliers and clean under running 
water.

 

Clean high-pressure nozzle: Remove dirt 
and debris from the nozzle bore, using a 
needle and rinse through with water from the 
front.

 

Check water flow quantity.

 

Slight leakage from the appliance pump is 
normal. If the leakage increases contact the 
authorized customer service.

 

Detach spray lance from the trigger gun. 
Work only with the trigger gun.

 

Clean the detergent suction hose filter.

 

Check the detergent suction hose for kinks.

Maintenance and care

Maintenance

Storage

Frost protection

Spare parts

Troubleshooting

Appliance is not running

Pressure does not build up in the appliance

Strong pressure fluctuations

Appliance is leaking

No detergent infeed

 $

!"

Содержание K 2.110 M

Страница 1: ...IJKLM NO5B7 PQRRSTU V8 W61X65 VV Y Z 306 C D2 E 0Z 306 8 2 B3 8 F 0 88 D2 E 0 306 88V 0123 4560763 8 9 62360 8 5260 6 2 5 1 A 60 B C 5 B 8 DE 0 B6 D F3 GHHIJKLM NO5B7 PQRRSTU V8 W61X65 VV Y Z 306 C D2...

Страница 2: ...2...

Страница 3: ...htm The warranty terms published by the relevant sales company are applicable in each country We will repair potential failures of your appliance within the warranty period free of charge provid ed t...

Страница 4: ...nsory or men tal capabilities The appliance must not be operated by chil dren or persons who have not been instruct ed accordingly Children should be supervised to prevent them from playing with the a...

Страница 5: ...delivered with appliance prior to start up Illustrations on Page 2 Illustration Insert the transport handle and screw in Illustration Insert the transport wheels and lock them Illustration Pull out th...

Страница 6: ...r local dealer or request information directly from K RCHER Pull detergent suction hose as far as is re quired out of the housing Suspend end of detergent suction hose in a container filled with deter...

Страница 7: ...e and remove the mains plug prior to any care and maintenance work Repair works may only be performed by the au thorized customer service Pull on the lever of the trigger gun the device will switch on...

Страница 8: ...s II Protection class IP X5 Water connection Max feed temperature 40 C Min feed volume 8 I min Feed pressure 0 2 1 2 MPa Performance data Working pressure 8 MPa Max permissible pressure 11 MPa Water f...