60
English 5.906-548.0 Rev. 00 (04/12)
Reset the gun switches since the most recent
gun service.
Turn off the appliance.
Turn the thermostat to 63 °C.
Rotate the service switch into the "SET" position
and hold it there.
Turn on the appliance.
–
The gun switches since the last gun service are
deleted.
–
The service counter gun (SCTR_PISTOLE) will be
increased by 1.
–
The fault memory will be deleted.
6.1.16Gun services
Function
adjustment
Display
Significance
63 °C
SCTR_PISTOLE
Number of gun services.
The value is shown digit by digit
via the indicator lamps.
The display is repeated after a
pause.
Example:
11 gun services have been per-
formed since the device was first
used.
The indicator lamps light up in the
following sequence:
PAUSE
Digit value "0"
Digit value "1"
Digit value "2"
Digit value "3"
Digit value "4"
Digit value "5"
Digit value "6"
Digit value "7"
Digit value "8"
Digit value "9"