![Kärcher HDS 7/12 M Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/karcher/hds-7-12-m/hds-7-12-m_service-manual_4209114074.webp)
74
English
5.906-432.0 Rev. 00 (06/15)
1 Turning handle
Screw in the twist grip of the pressure and volume reg-
ulation on the pump all the way to the stop (towards
"+").
Pull off the rotary handle.
1 Adjusting screw
2 Counter-nut
Loosen counter-nut.
Completely screw in the adjustment screw.
Install the stop valve on the high-pressure connection.
Turning on the appliance.
1 Safety block
2 Safety valve
3 Adjustment screw, safety valve
Slowly close the stop valve.
Observe at what pressure water is tripping.
(Nominal value: 20 bar above max. working pressure, see
technical data)
If the pressure is too high, turn the adjustment screw on
the safety valve to the left (relax the pressure spring).
If the pressure is too low, turn the adjustment screw on
the safety valve to the right (tension the pressure
spring).
Seal the adjustment screw.
Adjust the pressure/ volume regulation.
7.3
Adjust safety valve
Содержание HDS 7/12 M
Страница 14: ...14 English 5 906 432 0 Rev 00 06 15...
Страница 58: ...58 English 5 906 432 0 Rev 00 06 15 6 28 Functional diagram of pressure water operation water cooled motor...
Страница 60: ...60 English 5 906 432 0 Rev 00 06 15 6 29 Functional diagram vacuuming operation...
Страница 125: ...English 5 906 432 0 Rev 00 06 15 125 Circuit diagram 0 089 021 0 HDS 7 12...
Страница 126: ...126 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 025 0 HDS 8 18 HDS 9 18...
Страница 128: ...128 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 088 952 0 HDS 10 20 HDS 12 18...
Страница 130: ...130 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 9026 0 HDS 13 20...