1 Connection trigger gun
2 Connecting pin
3 Ceramic disc on gun side
4 Ceramic disc on spray pipe side
5 Casing of rotating regulator
6 Handle of rotary regulator
7 Spray lance connection
The pressure and volume regulation is designed as a rota-
ry regulator between the trigger gun and the spray lance.
There are two ceramic discs within the high pressure chan-
nel.
A ceramic disc is rigidly connected with the connection of
the trigger gun. The other ceramic disc is connected to the
rotating regulator and therefore adjustable. Offset holes in
the ceramic discs can adjust the flow volume and the pres-
sure when rotating the discs.
This illustration shows the two overlapping ceramic discs
and the water flow (blue) with different opening angles
(from 0° to 90°).
With the minimal setting, the water flows through a small
hose in the middle of the ceramic discs.
Note
The rotary regulator cannot be repaired and must be re-
placed as a complete unit.
Water flow with opening angle 0° - 90°
6.27 Pressure and volume regulation
Содержание HDS 7/12 M
Страница 14: ...14 English 5 906 432 0 Rev 00 06 15...
Страница 58: ...58 English 5 906 432 0 Rev 00 06 15 6 28 Functional diagram of pressure water operation water cooled motor...
Страница 60: ...60 English 5 906 432 0 Rev 00 06 15 6 29 Functional diagram vacuuming operation...
Страница 125: ...English 5 906 432 0 Rev 00 06 15 125 Circuit diagram 0 089 021 0 HDS 7 12...
Страница 126: ...126 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 025 0 HDS 8 18 HDS 9 18...
Страница 128: ...128 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 088 952 0 HDS 10 20 HDS 12 18...
Страница 130: ...130 English 5 906 432 0 Rev 00 06 15 Circuit diagram 0 089 9026 0 HDS 13 20...