background image

English Operating 

Instructions

28

Mains connection

See technical data and rating plate for
connected load.

 Warning!

It is not permissible to exceed the
maximum permissible mains impedance at
the electrical terminal (see Technical Data).

 Warning!

Whenever socket is changed, check
direction of rotation of motor

 If direction of rotation is correct, powerful

jet of air will be felt at exhaust-gas
opening of burner.

 If the direction of rotation is

wrong: Change the poles at the unit
plug. See Fig. 18.

!

  When an extension cable is used it

should always be complety unwound
and have an adequate cross-section.

Operation

 Warning!

(Applies only to HDS Super M / MX Eco)

Lengthy operation of the unit can lead to
vibration-related circulatory disturbances of
the hands.

A generally valid use duration cannot be
specified, since this is dependent upon
several influence factors:

 Personal predisposition to bad

circulation(frequent suffering from cold
fingers, pins and needles in fingers).

 In low ambient temperatures. Wear

warm gloves to keep hands warm.

 Gripping tightly impedes circulation.

 Continuous operation is more

detrimental than operation interrupted by
breaks.

We recommend a medical examination if
the unit is regularly used for extensive,
continuous operation and the
corresponding symptoms (such as, for
example, pins and needles in fingers or
cold fingers) are recurrentp.

Switch on the machine

!

  Set unit switch (item 23) to "I"

Ready for working indicator lamp (item28)
is lit

 Warning!

The temperature regulator (item 24) must
be set to "0", since otherwise the burner
possibly switches on

Unit starts up briefly and is switched off as
soon as operating pressure is reached.

Stop the unit immediately when one of the
indicator lamps (items 25-27) light up
during operation. Eliminate fault, refer to
Faults.

Fig. 9

!

  Release the safety of the handgun (A)

Actuation of handgun switches unit back on
again.

Bleed pump if no water emerges from high-
pressure nozzle. See problems, "Unit does
not build up pressure"

Содержание HDS 655 M Eco

Страница 1: ...www kaercher com 5 961 306 A2008544 05 04 HDS Super M Eco HDS Super MX Eco HDS 655 M Eco HDS 695 M Eco HDS 695 MX Eco HDS 895 M Eco HDS 895 MX Eco HDS 1195 S Eco HDS 1195 SX Eco...

Страница 2: ...is Italiano Nederlands Espa ol Portugu s Dansk Norsk Svenska Suomi Magyar esky Slovensko Polska Rom ne te T rk e Slovensky Hrvatski Srpski 41 7 24 59 77 94 147 111 128 164 181 198 247 214 231 264 282...

Страница 3: ......

Страница 4: ...1 2 3 4 5 6a 6b 7...

Страница 5: ...8 9 10 11a 11b 12 13 14...

Страница 6: ...15 16 17 18 19...

Страница 7: ...Inform retailer immediately of any transportation damage Environmental protection Please dispose of packaging environmentally responsibly The packaging materials are recyclable Please do not throw the...

Страница 8: ...the chassis 15 Steel pipe 16 Pressure and flow control 17 Swivel caster with parking brake 18 Water connection with strainer 19 High pressure connection 20 Handgun with high pressure hose 22 Electric...

Страница 9: ...rd tap water Is is metered in at the inlet in the water reservoir one drop at a time By the manufacturer metering is set to a mean water hardness For other water hardnesses request services of a K rch...

Страница 10: ...le bends direction of turns clockwise Mounting of spare high pressure hose Fig 7 Mounting handle Fig 8 Water connection See Technical Data for connected loads Install supply hose at water connection i...

Страница 11: ...ad circulation frequent suffering from cold fingers pins and needles in fingers In low ambient temperatures Wear warm gloves to keep hands warm Gripping tightly impedes circulation Continuous operatio...

Страница 12: ...or a lengthy period See Fig 10 Measuring out cleaning agents Use cleaning agents sparingly to protect the environment The cleaning agent must be appropriate for the surface to be cleaned Using the cle...

Страница 13: ...pressure jet Operation with cold water Removal of slight contamination and rinsing e g gardening implements patio tools etc Set operating pressure as required Set temperature control item 24 to 0 Ope...

Страница 14: ...metering valve item 30 to 0 Set unit switch item 23 to I Actuate handgun and flush unit for approx 1 min Stopping machine Set unit switch item 23 to 0 Shut off water supply Switch the pump briefly on...

Страница 15: ...k Always use genuine spare parts Turn off unit prior to all work see After every operation Set unit switch item 23 to 0 Pull power plug out of socket Shut off water supply Actuate handgun to depressur...

Страница 16: ...antity to be used Faults Ready for working indicator lamp item 28 goes out Motor overloaded overheated Set selector switch to 0 and allow engine to cool off for at least 5 min Have unit checked by Aft...

Страница 17: ...ssure system Check high pressure system and connections for leaks Unit does not draw in cleaning agent Run the unit with an opened cleaning agent metering valve and a closed water supply until the flo...

Страница 18: ...and conditions issued by our responsible sales company apply in every country Within the warranty period any faults in the unit will be rectified free of charge provided that the problem was caused by...

Страница 19: ...ed Adjustment can only be made by After Sales Service Safety valve The safety valve opens if the overflow valve or pressure switch is defective The safety valve is set at the factory and sealed Adjust...

Страница 20: ...EN 61000 3 2 2000 DIN EN 61000 3 3 1995 A1 2001 HDS 695 HDS 895 DIN EN 61000 3 11 2000 HDS 655 HDS 1195 HDS Super Applied national standards Applied conformity valuation method Appendix V Measured sou...

Страница 21: ...l h 6 7 l min 350 l h 5 8 l min Operating pressure steam max 3 2 MPa 32 bar max 3 2 MPa 32 bar Steam nozzle part number 4 766 023 4 766 023 Operating temperature Hot water max 95 C max 95 C Steam 98 1...

Страница 22: ...7 8 l min Operating pressure steam max 3 2 MPa 32 bar max 3 2 MPa 32 bar Steam nozzle part number 4 766 023 4 766 023 Operating temperature Hot water max 95 C max 95 C Steam 98 155 C 98 155 C Cleaning...

Страница 23: ...3 18 MPa 30 180 bar Flow rate steam 600 l h 10 l min Operating pressure steam max 2 8 MPa 28 bar Steam nozzle part number 4 766 024 Operating temperature Hot water max 95 C Steam 98 155 C Cleaning ag...

Страница 24: ...405...

Страница 25: ...406...

Отзывы: