![Kärcher HDS 6/14-4 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/karcher/hds-6-14-4/hds-6-14-4_original-instructions-manual_4234082020.webp)
– 7
DANGER
Risk of injury by inadvertent start-up of appliance and
electric shock. Prior to all work on the appliance, switch
off the appliance and pull the power plug.
Figure 14
Exchange the poles at the appliance plug.
–
No line voltage, see "Appliance is not running".
–
Water shortage
Check water supply, check connections.
–
Leak in the high pressure system
Check high pressure system and connections for
tightness.
–
Fault in the voltage supply or current pickup of the
motor too high.
Check main connections and mains fuse.
Inform Customer Service.
–
Engine overload/overheat
Set the appliance switch to "0/OFF“.
Allow device to cool down.
Turn on the appliance.
–
Error occurs repeatedly.
Inform Customer Service.
–
The exhaust temperature limiter has been triggered.
Set the appliance switch to "0/OFF“.
Allow device to cool down.
Turn on the appliance.
–
Error occurs repeatedly.
Inform Customer Service.
–
Obstructed reed switch in the lack of water fuse or
magnetic piston stuck.
Inform Customer Service.
–
The flame sensor turned the burner off.
Inform Customer Service.
–
Fuel tank empty.
Refill fuel.
–
System care bottle empty.
Replace the system care bottle.
–
Detergent tank is empty.
Refill detergent.
–
No power
Check power connection/conduit.
–
Air within the system
Vent pump:
Set dosing value for detergent to "0".
With open hand spray gun turn device on and off
multiple times with the device switch.
Open and close the pressure/quantity regulation at
the pump unit with the hand spray gun open.
Note:
By dismantling the high pressure hose from the
high pressure connection the venting process is accel-
erated.
If detergent tank is empty, refill.
Check connections and conduits.
–
Pressure is set to MIN
Set pressure to MAX.
–
Sieve in the water connection is dirty
Clean sieve.
Clean the fine filter; replace it, if necessary.
–
Amount of water supply is too low.
Check water supply level (refer to technical data).
–
Pump leaky
Note:
3 drops/minute are allowed.
With stronger leak, have device checked by cus-
tomer service.
–
Leak in the high pressure system
Check high pressure system and connections for
tightness.
Leave device running with open detergent dosage
valve and closed water supply, until the swimmer
tank is sucked empty and the pressure falls to "0".
Open the water supply again.
If the pump still is not sucking in any detergent, it could
be because of the following reasons:
–
Filter in the detergent suck hose dirty
Clean filter.
–
Backflow valve stuck
Remove the detergent hose and loosen the back-
flow valve using a blunt object.
–
Fuel tank empty.
Refill fuel.
–
Water shortage
Check water supply, check connections.
Clean sieve in the water shortage safe guard.
–
Fuel filter dirty
Change fuel filter.
–
No ignition spark
If device is in use and no ignition spark can be seen
through the viewing glass, have device checked by
customer service.
Troubleshooting
Indicator lamp for rotation direction will blink
(3-phase appliances only)
Indicator lamp "Ready for use" turns off
Indicator lamp service
1x blinking
2x blinking
3x blinking
4x blinking
5 x blink
6 x blink
Fuel indicator lamp glows
Indicator lamp system care is illuminated
Indicator lamp for detergent glows
Appliance is not running
Device is not building up pressure
Device leaks, water drips from the bottom of
the device
Device turns on and off while hand spray gun
is closed
Device is not sucking in detergent
Burner does not start
23
EN