Operating Instructions
English
29
Setting cleaning temperature
!
Set the remperature regulator (item 24)
to the required temperature
30°C to 90°C
Hot water cleaning
100°C to 150°C
Cleaning with steam
!
Replace high-pressure nozzle by the
steam nozzle (see operation using
steam)
Setting operating pressure and
flow rate
Fig. 10
—
Turning control spindle
clockwise: Increasing operating
pressure (MAX)
—
Turning it counterclockwise: Reducing
operating pressure (MIN)
Servopress control
!
Set the temperature regulator (item 24)
to max. 98°C.
!
Set regulator to maximum operating
pressure.
Fig. 9
Adjust operating pressure and flow rate by
turning (infinitely variable) at the pressure
and flow control (B) (+/-)
Set pressure on unit if use is to be made of
reduced pressure for a lengthy period.
See Fig. 10
Measuring out cleaning agents
—
Use cleaning agents sparingly to protect
the environment
—
The cleaning agent must be appropriate
for the surface to be cleaned.
!
Using the cleaning agent metering valve
(item30) set the concentration of the
cleaning agent as specified by the
manufacturer
Approximate values at maximum operating
pressure
Intended use
For cleaning: machines, vehicles, buildings,
tools, facades, patios, gardening
implements, etc.
Warning!
—
Heed appropriate safety regulations for
use at petrol stations or in other
hazardous environments.
Please ensure waste water containing
mineral oil
does not contaminate soil, lakes and rivers
or the sewerage system. Therefore, please
wash engines and underbodies only in
appropriate washing installations provided
with oil traps.
Working with high-pressure nozzle
Spray angle is crucial to efficiency of high-
pressure jet.
Use is normally made of 25°fan jet nozzle
(included).