English
5.906-441.0 Rev. 01 (06/10)
13
A Tightening torque 35 Nm
The speed control lowers the motor speed when the hand spray
gun is closed.
–
Default setting of the carburator flap while motor is not running:
42 mm
–
Grease all O-rings with silicone grease 6.288-028.0 prior to in-
stallation.
1
Fastening boring for the speed control in the cylinder head of
the high pressure pump
2
Fastening boring for the thermal valve
4.5.6
Speed control