Technical Specifications

HD 2.3/15 C 

Ed

1.150-611.0

HD 3.0/20 C 

Ea

1.151-610.0

HD 2.3/14 C 

ED Food

1.150-614.0

Mains connection

CDN/CSA/USA

Voltage

V

120

240

120

Type of current

Hz

1~60

1~60

1~60

Connected load

hp / kW

3,2 / 2,4

6 / 4,5

3,2 / 2,4

Supply fuse (delayed-action, char. C)

A

20

20

20

Extension cable 30 m

AWG / mm

2

12 / 2,5

11 / 2,5

12 / 2,5

Water connection

Supply temperature max.

°C

60

60

80

Supply volume min.

gpm / l/min

3,0 / 11,4

4,0 / 15,1

3,0 / 11,4

Supply hose – minimum length 

ft / m

25 / 7,5

25 / 7,5

2,5 / 7,5

Supply hose – minimum diameter

inches

3/4

3/4

3/4

Suction height from an open container 
20 °C

ft / m

1,6 / 0,5

1,6 / 0,5

1,6 / 0,5

Supply pressure max.

psi / MPa

145 / 1

145 / 1

145 / 1

Performance data

Operating pressure

psi / MPa

1500 / 10,3

2000 / 13,8

1400 / 9,7

Max. operating overpressure

 

(safety valve)

psi / MPa

1800 / 12,4

2300 / 15,9

1700 / 11,7

Flow rate

gpm / l/min

2,3 / 8,7

3,0 / 11,4

2,3 / 8,7

Detergent intake

gpm / l/min

0,16 / 0,62

0,16 / 0,62

0,16 / 0,62

Recoil force of the handgun

N

21

21

21

Sound emission

Sound pressure level 
(EN 60704-1)

dB (A)

72

77

72

Garanted sound pressure level 
(2000/14/EC)

dB (A)

86

91

86

Vibrations of unit 

/ total of vibration (ISO 5349)

Handheld gun

m/s²

2,2

2,0

2,2

Spray lance

m/s²

2,2

2,3

2,2

Dimensions

Length

mm

360

360

360

Width

mm

375

375

375

Height

mm

925

925

925

Weight without accessories

kg

23

24

23

Oil quantity, pump

l

0,35

0,35

0,35

Oil type, pump

SAE 0W40

SAE 15W40 SAE 0W40

Содержание HD 2.3/15 C Ed

Страница 1: ...www kaercher com HD 2 3 15 C Ed HD 3 0 20 C Ea HD 2 3 14 C Ed Food 5 961 971 0 03 07...

Страница 2: ...2 English 4 Fran ais 13 Espa ol 22...

Страница 3: ...3...

Страница 4: ...ger Gun Safety Lock PREVENTS the trigger from accidentally being engaged This safety feature DOES NOT lock trigger in the ON position Do not use extension cord with this unit GROUNDING INSTRUCTIONS Th...

Страница 5: ...se of penetration seek medical aid immediately This system is capable of producing 10400 kPa 1500 PSI HD 2 3 15 C Ed 13000 kPa 2000 PSI HD 3 0 20 C Ea to avoid rupture and injury do not operate this p...

Страница 6: ...ad these operating instructions and take special note of the accompanying booklet Safety Instructions for High Pressure Clean ers No 5 951 949 Use of the cleaner Use this appliance exclusively for cle...

Страница 7: ...er Mount the accessories Mount nozzle on the spray lance see markings on the top of the setting ring Fit the spray lance to the hand held spray gun For appliances without hose reel Undo push handle cl...

Страница 8: ...f necessary allow unit to continue running for 10 sec onds and then switch off Repeat this pro cedure several times Switch off the unit and screw the nozzle back on Operating the unit Danger Observe t...

Страница 9: ...ugh for one minute Interrupting the operation Release lever of the handgun the unit switches off Retract lever again and the unit switches on again Switching the unit off Set unit switch to 0 and pull...

Страница 10: ...ng hours Change the oil For oil quantity and type see Technical Specifications Undo the fastening screw remove the hood remove the oil tank cover tilt unit Drain oil into a suitable container Fill slo...

Страница 11: ...or check it for leaks remove obstruction Seek the help of Customer Service if nec essary Spare parts You will find a list of spare parts at the end of these operating instructions Warranty The warrant...

Страница 12: ...ner 20 C ft m 1 6 0 5 1 6 0 5 1 6 0 5 Supply pressure max psi MPa 145 1 145 1 145 1 Performance data Operating pressure psi MPa 1500 10 3 2000 13 8 1400 9 7 Max operating overpressure safety valve psi...

Страница 13: ......

Отзывы: