6
English
5.906-441.0 Rev. 01 (06/10)
1
Cover, switch box
2
Indicator lamp lack of water fuse (option)
3
Indicator lamp operation status / malfunction
4
Appliance switch (S1)
5
Fuse (F1), 1AT
6
Circuit board (A1)
7
DIP switch
1 not used
2 Leakage monitoring (default setting: ON)
3 not used
4 30 minute continuous operation/continuous break (default
setting: ON).
8
Electronics system
9
Fuse (F2), 2AT
10 Control transformer (T1)
11 Contactor (K1)
12 Soft starter board (A2)
4.2
Switch box HD 13/35-4 Cage, HD 9/50-4 Cage