6
OPERATING INSTRUCTIONS
Step 8
Move the engine stop switch to the ON
position.
For more details see engine manual.
Step 9
Pull the starter handle.
If the engine fails to start after 3 pulls,
squeeze the trigger gun to release
pressure, and repeat step.
After the engine warms up enough to run
smoothly, move choke rod to OFF position.
Important!
Do not run the engine with a high or low oil
level as this can cause engine damage.
If you have further questions regarding the
engine, please refer to the engines
operating manual included with the unit.
Step 1
Check oil level. Oil level should always be
between the FULL and ADD marks on the
dipstick.
Be sure the machine is level when checking
the oil level. (Refer to the engines operating
manual for seasonal grades.).
We recommend that the oil be changed after
the first 5 hours of use, then once every 50
hours.
Step 2
Fill gas tank with unleaded gasoline.
Do not use leaded gasoline.
Step 3
Connect the high pressure hose to the units
high pressure outlet.
Step 4
Connect garden hose to units water inlet.
Step 5
Connect garden hose to the cold water
source and turn water on completely.
Do not use hot water.
Step 6
Trigger the gun to eliminate trapped air, wait
for a steady flow of water to emerge from
the spray nozzle.
Step 7
Open fuel valve. Pull the choke rod to the
ON position (on a warm engine, leave the
choke rod in the OFF position).