14
English
It is highly recommended to use
Kärcher Pump Guard (part number
9.558-998.0) before winter storage
and during the cleaning season to
protect the pump from freezing and
premature wear.
►
Turn engine switch to the OFF
position.
►
Disconnect all hoses.
►
Unscrew cap from Pump Guard
bottle.
►
Remove internal seal.
►
Reattach cap to Pump Guard bottle
and remove black protective cap.
►
Screw bottle into water inlet on
pressure washer pump and squeeze.
►
With ignition OFF, pull starter rope
until fluid starts to exit.
►
Unscrew bottle. Store or dispose
properly.
If Kärcher Pump Guard is unavailable,
perform the following:
►
Disconnect all water connections.
►
Turn on the machine for a few
seconds, until the water which
remained in the pump exits. Turn off
engine immediately.
Failure to follow the above directions
may result in damage to the pump
assembly and accessories and void
the warranty.
Do not allow high pressure hose to
become kinked.
Store machine and accessories in a
room which does not reach freezing
temperatures. DO NOT store near
furnace or other sources of heat as it
may dry out the pump seals.
Pump Inspection
You should routinely make a visual
inspection of the pressure washer’s
pump. If you notice oil leaking around
the pump seals, you should take the
pressure washer to a Kärcher
Authorized Service Center for repair.
(You can locate a service center in
your area online at:
www.karcher-service.com).
Carry out maintenance tasks for the
engine according to the specifications
provided in the operating instructions
provided by engine manufacturer.
Winterizing & Long-Term
Storage
Maintenance Instructions
Pump
Engine
Содержание G 2200
Страница 1: ...English 4 Español 20 Français 40 8 641 220 0 12 15 G 2200 ...
Страница 2: ...G 2200 ...
Страница 3: ......