EACH TIME AFTER USAGE
Set ON/OFF switch to „0“
Dissipating pressure
Open air supply valve
Open safety valve and dissipate
pressure.
Pull power plug
Switching off the cleaner
Coil up connecting cable
Coil up high-pressure hose and
attach to handle
Place hand gun in holder
If period of non-operation is more
than 1 week drain and flush
pressure vessel.
If period of non-operation is less
than 1 week, cleaning
agent/disinfectant can be left in
pressure vessel.
In this case, dismantle and rinse
nozzle.
Draining pressure vessel
∗
Avoid contact with eyes and skin
∗
Observe cleaning
agent/disinfectant manufacturer's
notes on safety and handling
∗
Always wear protective clothing,
mask, protective goggles, rubber
boots and rubber gloves
−
Pull power plug
−
Dissipate pressure
Pull off air hose
If vessel is nearly empty (light):
Slacken off bracket and lift out tank.