Maintenance
1.
If your machine is equipped with a detail sump,
dump the contents of the detail sump into the main
sump chamber.
2.
Remove oil and grease from the cleaning solution
using the oil skimmer system (See
Using the Oil
Skimmer System
).
3.
Position the three-way wash solution valve as
shown.
4.
Close and latch the door.
5.
Run the machine through a 30-minute wash cycle.
NOTE: While the sump sweep is operating, monitor
the outlet pressure on the filter system to ensure that
it does not drop below 30 psi. If the pressure drops
below 30 psi, immediately stop the machine and
either clean or replace the filter bag(s) (See
Cleaning
the Filters
).
6.
After the machine stops, position the three-way
wash solution valve as shown.
7.
Add the appropriate amount of detergent
and run
the machine through a 30-minute wash cycle. Use
a pH kit to determine the proper amount of
detergent to add.
NOTE:
Manufacturers detergent is the only
detergent approved for use with our automatic parts
washers. It is specially formulated with rust inhibitors
and anti-foaming agents to optimize performance and
minimize maintenance. The use of any other
detergent during the warranty period will void the
warranty.
Manual Sump Clean out
To manually clean out the sump, perform the following
procedure:
1.
If your machine is equipped with a detail sump,
dump the contents of the detail sump into the main
sump chamber.
2.
Remove oil and grease from the cleaning solution
using the oil skimmer system (See
Using the Oil
Skimmer System
).
3.
If your machine is equipped with the Auto-Fill
feature, turn off the water at the supply line.
4.
Remove both sump covers, then drain the wash
solution from the sump chamber. To drain the
solution either use the sump drain or a small
submersible pump.
5.
Remove sand and other debris from the bottom of
the sump chamber and the detail sump. To remove
the debris, either flush it out through the sump
drain or vacuum it out using a wet/dry vac. Dispose
of the debris in accordance with applicable local,
state, and federal regulations.
NOTE:
Take special care to ensure that the heating
element is free of debris. A buildup of debris around
the element will decrease heating performance and
may cause the element to overheat and fail.
6.
Refill the sump with fresh clean water.
7.
Replace the sump covers and heat the wash water
to operating temperature.
8.
Add the appropriate amount of detergent
and run
the machine through a 30-minute wash cycle. Use
a pH kit to determine the proper amount of
detergent to use.
NOTE: Manufacturers detergent is the only detergent
approved for use with our automatic parts washers. It
is specially formulated with rust inhibitors and anti-
foaming agents to optimize performance and
minimize maintenance. The use of any other
detergent during the warranty period will void the
warranty.
CUDA 7248 Operator’s Manual 9.801-712.0 - AA
Wash
Position
Sump
Sweep
Position