Operating Instructions BR/BD 530/530 XL/F BAT/Package
English
32
Troubleshooting
Risk of injury!
Before working on the unit, always
switch off the brush mode switch and
suction motor and pull out the battery
charger mains plug.
!
Drain off and dispose of dirty water and
any residual cleaning liquid.
If faults cannot be rectified with the aid of
this table, contact customer service.
!
Fault
Remedial action
Unit cannot be started.
Press in the overload fuse.
Check batteries; if required, replace.
Inadequate water flow rate.
Check fresh-water level; if required, top up tank.
Check hoses for blockages; remove any blockages.
Inadequate suction power.
Clean container cover seals and check for leaks;
if required, replace.
Clean fluff strainer.
Clean squeegee blades on the suction bar; if required,
replace.
Check suction hose for blockages; remove any
blockages.
Check suction hose for leaks; if required, replace.
Check whether metering valve on the dirty-water drainage
hose is closed.
Check the setting of the suction bar.
Unsatisfactory cleaning
result.
Check the brushes for wear and suitability and, if required,
replace.
Brushes do not rotate.
Check whether the brushes are blocked by foreign
objects; if required, remove foreign objects.