6
Fault
Remedy
Appliance cannot be
started
Check if the mains plug is connected.
Insufficient water
quantity
Check fresh water level, refill tank if necessary.
Open the lock of the fresh water reservoir. If a vacuum is detected
when the tank is opened, clean the ventilation valve in the lock of
the fresh water reservoir.
Clean the water distributor (see chapter "Cleaning the water dis-
tributor").
Pull off the valve with filter on the fresh water reservoir (Fig. 4, see
inside front cover) and rinse in lukewarm water.
Fresh water reservoir
drips when refilled
Pull off the valve with filter on the fresh water reservoir (Fig. 4, see
inside front cover) and rinse in lukewarm water.
Insufficient vacuum
performance
Empty the dirt water reservoir.
Lock the waste water reservoir in place on the appliance.
Clean the seals between dirt water reservoir and cover and check
for tightness, replace if required.
Check that all vacuum bars are locked into place in the cleaning
head.
Suction bar plugged, clean.
Vacuum bar worn, replace if required.
Check that both suction tube parts are correctly attached to the
suction tube connection.
Check the suction tube and the suction channel in the cleaning
head for obstruction and remove if necessary (see "Cleaning suc-
tion tube").
Check whether the cable behind the tanks has been routed flat
and whether the included cover is attached.
Insufficient cleaning
result
Check the brush roller for wear, replace if required.
Brush does not turn
Check if foreign matters are blocking the brush roller; remove for-
eign matter if required.
Creaking sound,
brush does not turn
Slip clutch was triggered. Switch off the appliance, check/clean
the brush roller.