– 7
Pump switches
itself off and
back on (BPP
4000/48 and
BPP 4500/50)
Thermal protection fuse has
switched the pump off to pro-
tect from overheating or turned
it back on after it has cooled
off.
In order to prevent a repetition, the
system should be checked for leaks
and sealed.
Motor starts up
immediately af-
ter switch off
Pressure is not retained in the
system
Check connections including sealings
and control the water outlet.
The smallest of leakages can affect
the operation adversely.
Air pressure in the storage
boiler is too low.
Fill storage boiler with 2.0 bar. Refer
to Chapter "Maintenance" Figure A
Backflow valve does not close
properly
Check backflow valve on suction side.
Membrane in pressure tank is
defective
Replace membrane
Pump trans-
ports is reduc-
ing or
transported
quantity is too
low
Suction filter or backflow valve
contaminated
Clean suction filter or backflow valve
The quantity transported by
the pump depends on the
transport height and the con-
nected periphery
Keep max. flow height, see technical
data. If necessary, select a different
hose diameter or hose length.
Pre-filter is dirty
Remove the pre-filter and clean it un-
der flowing water.
Vibrating sound
while taking out
water
Membrane in pressure tank vi-
brates
Noise caused by operations and the
noise can be reduced by reducing the
pressure in the air filling of the storage
tank.
Fault
Cause
Remedy
Our Kärcher branch will be pleased to help you further in the case of questions or faults.
See address on the reverse.