5.906-510.0 Rev. 00 (12/10)
21
Measure the battery voltage several times while the
turbine is turned on.
Measure the battery voltage while the turbine is
turned on, shortly before the discharge end voltage is
triggered.
Current pickup:
Final discharge voltage:
Runtime indication:
Battery date:
With 12 volt battery blocks, the complete battery set
must be replaced in case of damage.
If the 6 volt battery blocks have reached the above
mentioned use time or the number of loading cycles,
replacing the battery block with a new one is no long-
er worth it. We recommend replacing the entire bat-
tery set.
If the use duration or the number of load cycles is be-
low the above values, it makes sense to replace a de-
fective battery block. However, the following
measures must be taken to adapt/balance the load of
the different battery blocks.
Remove the defective battery block.
Charge the remaining battery blocks and the new
battery block individually. You can use a laborato-
ry device for that. The load voltage must be set to
exactly 7.14 volts. The load current must not ex-
ceed 14 A / 100 Ah.
The load current must have decreased to under 4
A / 100 Ah at the end of the battery block.
6.5.1 Measurement - load test
Battery
block 1
Battery
block 2
Battery
block 3
Battery
block 4
Battery
block 5
Battery
block 6
6.5.2 Measurement - load test
Battery
block 1
Battery
block 2
Battery
block 3
Battery
block 4
Battery
block 5
Battery
block 6
6.5.3 Record further machine data
Drive motor
Ampere
Suction turbine
Ampere
Brush motor
Ampere
All consumers
during cleaning
Ampere
When does the
discharge end
voltage get trig-
gered?
Volt
How long was
the customer
able to work
with the appli-
ance when the
batteries were
still fully func-
tional?
Hours / minutes
Is indicated
near the bat-
tery terminal on
the battery
Date or code
6.6
Replacing a battery due to old age
Battery
Duration of use
Charging cycles
6 volt battery
block
6 months
100
12 volt battery
block
-----------
-----------
6.6.1 Adapting the load