5.906-510.0 Rev. 00 (12/10)
19
DIP switch 1:
The built-in battery type can be selected on DIP
switch 1.
ON: Gel battery
OFF: Lead battery
DIP switch 2:
The adjustment "Total discharge protection" can be
made on DIP switch 2.
ON: Gibli mode = once the battery is completely
discharged, the appliance will shut off. The appli-
ance cannot be used again until the battery is
charged.
OFF: Kärcher mode = once the battery is com-
pletely discharged, the appliance will shut off. The
appliance be run for 1 minute after switching it off
and back on, before it will shut off again due to to-
tal discharge.
Fault diagnosis function
Display in the battery status field by respective
blinking of LEDs.
4.19.2 DIP switch
5
Reading faults
Fault
Visualisation
Suction turbine
overload
LED1 LED 2 is lit
continuously
Brush motor over-
load
LED1 LED 3 is lit
continuously
Interruption of suc-
tion turbine
LED1 LED 4 is lit
continuously
Interruption of the
brush motor
LED1 LED 5 is lit
continuously