10
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
Pump does not
start
Buffer tank for permeate is full
Wait until the permeate is consumed.
Operator
Level switch Buffer tank is full is defective Check level switch.
Customer
Service
Start-up time of the control has not yet
been completed
Wait.
Operator
Pressure switch for water scarcity is defec-
tive
Check pressure switch; replace it, if required.
Customer
Service
Regeneration of the base exchanger is
running
Wait for regeneration to end.
Operator
No softened water is coming from the base
exchanger
Check the base exchanger.
Operator/
Customer
Service
Pump continu-
ously goes on
and off
Finest filter or active carbon filter is dirty
Check filter; replace the filter inlay, if required
Operator
Regeneration of the base exchanger is in-
complete
Add salt, add water and wait for brine formation (ap-
prox. 2 hours); start regeneration, check the base ex-
changer, if required.
Operator/
Customer
Service
Pump starts only
after several rins-
ing cycles
Too low mains water pressure
Check mains water supply; open the inlet valve fully,
if required.
Operator
Finest filter or active carbon filter is dirty
Check filter; replace the filter inlay, if required
Customer
Service
Permeate output
is too low; buffer
tank of permeate
is often empty
Water inlet temperature is too low
Measure the temperature of the softened water and
compare it with the technical data.
Operator
Operating pressure is too low
Reset the operating pressure.
Customer
Service
There are calcium or mineral deposits on
the filter surface of the RO membrane.
Decalcify the membrane; replace it, if necessary
Customer
Service
Level switch Buffer tank is "full" is defec-
tive
Check level switch.
Customer
Service
There are bacteria or algae deposits on
the filter surface of the RO membrane.
Rinse the membrane thoroughly for a long time; re-
place it if necessary. In future remember: Water is of
potable quality; avoid long idling periods.
Customer
Service
There are stains
on the car paint
during Top Care
(permeate has
not been ade-
quately deminer-
alised)
The mineral content of the softened water
is too high
Check conductivity of softened water.
Customer
Service
RO membrane has ruptured; defective
sealing
Replace washer or membrane. Check conductivity
Customer
Service
Mixing of permeate and softened water
Comparison of conductivity of the permeate from the
spray pipe and water from the buffer tank of perme-
ate.
Customer
Service
Transport
Storage
24
EN