16
English
1. Remove the suction head (see chapter
2. Loosen the screws of the tensioning
rings.
3. Remove the small deflector plate.
4. Remove and replace the filter.
5. Insert the new filter.
Ensure that the filter is inserted correctly
during installation.
6. Fit the tensioning rings and screw them
on.
Troubleshooting guide
DANGER
Risk of injury
Danger of the device unintentionally start-
ing and danger of electric shock
Switch off the device and unplug the mains
plug before performing any work on the de-
vice.
Have all checks and work on electrical
parts performed by an qualified technician.
The motor (suction turbine) does not
start up
No electrical voltage present
Check the socket and the power supply
fuse.
Check the mains cable and the mains
plug of the device.
The suction power decreases
Nozzle, suction hose or suction pipe
clogged.
Check the nozzle, the suction hose and
the suction pipe and clean if necessary.
The filter is dirty.
Clean the filter.
Emptying the liquid container takes a
long time
The drain hose is kinked or blocked.
Check and, if necessary, clean the drain
hose.
Customer Service department
If the malfunction cannot be corrected, the
device must be checked by the Customer
Service department.
Warranty
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Technical data
IVR-L 100/30 Sc IVR-L 100/40 Sc
Electrical connection
Mains voltage
V
400
400
Phase
~
3
3
Power frequency
Hz
50
50
Degree of protection
IPX4
IPX4
Protection class
I
I
Nominal power
W
3000
4700
Power protection (slow-blowing)
A
16
32
Dimensions and weights
Typical operating weight
kg
141
168
Length x width x height
mm
855 x 760 x 1770 855 x 760 x 1890
Ambient conditions
Ambient temperature
°C
+40
+40