English
13
DANGER
Risk of electric shock. Turn off the appliance and re-
move the mains plug prior to performing any care and
maintenance work.
Repair work and work on the electrical components may
only be performed by an authorised customer service.
You can rectify minor faults yourself with the help of the
following overview.
If in doubt, please consult the authorized customer ser-
vice.
Push the lever of the trigger gun, the device will
switch on.
Check whether the voltage indicated on the type
plate corresponds to the voltage of the mains sup-
ply.
Check the mains connection cable for damages.
Motor overloaded, the motor circuit breaker has
tripped.
–
Turn off the appliance "0/OFF".
–
Allow the device to cool down for
one hour
.
–
Switch on the device and put it into operation again.
If the malfunction occurs repeatedly, have the de-
vice checked by the customer service.
Voltage reduction due to weak mains supply or when
using an extension cable.
Upon switch-on, push the lever of the trigger gun
first and then switch the power switch to "I/ON".
Check setting at the spray lance.
Check water supply for adequate delivery rate.
Pull out the sieve in the water connection using flat-
nose pliers and clean under running water.
Remove air from appliance before operation.
Switch on the appliance without connection the HP
hose (max. 2 minutes) and run it until the water dis-
charging from the HP outlet is free of bubbles.
Switch off appliance and reconnect HP hose.
Clean high-pressure nozzle: Remove dirt and de-
bris from the nozzle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
Dropwise leakage of the device is normal for tech-
nical reasons. If the leakage increases contact the
authorized customer service.
Turn the 3-in-1 multi jet spray lance to detergent
nozzle "MIX".
Check whether the Plug 'n' Clean detergent bottle
is placed into the detergent connection facing
down.
Check / replace the batteries
Decrease the distance between high-pressure gun
and high-pressure cleaner.
Couple it to the high-pressure cleaner again.
Switch off the device and pull the
mains plug out of the socket.
After 20 seconds, insert the power cord
back into the socket and switch the de-
vice on.
If the malfunction occurs repeatedly, have
the device checked by the customer ser-
vice.
If the pressure regulation on the high-pressure gun is
defective (electronic defect, battery empty, etc.), the
high-pressure cleaner continues operating at the level
that was last set.
To activate emergency operation at the maximum level:
Switch off the device and pull the mains plug out of
the socket.
Insert the power cord back into the socket and
switch the device on.
Only use original accessories and spare parts, they en-
sure the safe and trouble-free operation of the device.
For information about accessories and spare parts,
please visit www.kaercher.com.
KÄRCHER UK Limited operates a helpline allowing
customers to discuss any problems experienced with
our products.
The helpline operates during normal business hours
and may be busy at peak periods.If you have difficulty
getting through we would ask that you try to contact us
again later in the day.
The helpline number is 01295 752200, open from
8.30 am to 5.00 pm
Monday to Friday.
It helps us if you have the model number and data plate
details to hand before making your call so that we can
assist you with your query more effectively.
Alternatively you may write to us at the address
below
:
KÄRCHER UK Ltd
Kärcher House
Beaumont Road
Banbury
Oxon, OX16 1TB
or E-mail us
:
Troubleshooting
Appliance is not running
Appliance does not start, motor hums
Pressure does not build up in the appliance
Strong pressure fluctuations
Appliance is leaking
No detergent infeed
No pressure indicator on the trigger gun
Error messages
Emergency operation
Accessories and Spare Parts