BR/BD 75/140 R, BR/BD 90/140 R
Unit Functions
Page 11 / 71
New Unit Information 03.2004
Central battery connector
1
Connection cable from the block battery
2
Connection cable (auxiliary contact S32)
to the control panel
to the main control printed
circuit board
3
Connection cable with the main control
printed circuit board (A1)
4
Central connector (X1) - lower section
5
Central connector (X1) - upper section
with handle
EMERGENCY STOP function
All the unit’s electrical components are connec-
ted to the block battery via the central connector.
If the upper section (5) is pulled off, the whole unit
becomes isolated and the electromagnetic bra-
ke is activated in the front wheel and the unit is
braked.
4
1
5
and
ORIGINAL
REVISED
Note:
An external battery charger is connected to
the central connector-upper section (5).
2
3
ORIGINAL
REVISED