Operating Manual HDS Standard 9.808-214.0
13
PRESSURE W
ASHER
OPERA
TOR’S MANU
AL
PREVENTIVE MAINTENANCE AND SERVICE
MAINTENANCE
WARNING: Unauthorized machine modification or
use of non-approved replacement parts may cause
personal injury and/or property damage and will void
the manufacturer warranty.
DANGER
:
Risk of injury by inadvertent start-up of
appliance and electric shock. Prior to all work on
the appliance, switch off the appliance and pull the
power plug.
MAINTENANCE INTERVALS
Weekly
• Clean the sieve in the water connection.
• Clean the fine filter.
• Clean the fuel sieve.
• Check oil level.
ATTENTION: Risk of damage! In case of lacteous oil
inform Kärcher customer service immediately.
Monthly
• Clean filter at the detergent suck hose.
Every 500 operating hours, at least annually
• Oil change.
• Have the maintenance of the device performed by the
customer service.
MAINTENANCE WORKS
Clean the sieve in the water connection
• Take out sieve.
• Clean sieve in water and reinstall.
Cleaning the fine filter
• Unpressurize the appliance.
• Unscrew the fine filter from the pump head.
• Remove the fine filter and the filter insert.
• Clean the filter with clean water or compressed air.
• Reinstall in reverse sequence.
Clean filter at the detergent suck hose
• Take out detergent suck supports.
• Clean filter in water and reinstall.
Oil change
• Ready a catch bin for appr. 0.26 gal/1 Liter oil.
• Loosen release screw.
Dispose of old oil ecologically or turn in at a gathering
point.
• Tighten release screw.
• Fill oil slowly up to the MAX marking.
Note:
Air pockets must be able to leak out.
For oil type refer to technical specifications.
Proper Pump Care
•
DO NOT
pump acids.
•
DO NOT
allow pump to run dry.
• Winterize if storing in freezing temperatures, refer to
Storage
for details.
• Use a water softener on the water system if known to
be high in mineral content.
• Use only high quality detergents and follow manufacturer’s
mix recommendations.
• Flush the system with clear water immediately after
using detergent solutions.
• Clean filter screen on detergent inlet line periodically.
• Flush the pressure washer system with antifreeze if
storing for an extended period of time, refer to
Storage
for details.
Unloader Valve
WARNING: The unloader valve on this pressure
washer has been factory set and sealed and is a field
nonadjustable part. Tampering with the factory setting
may cause personal injury and/or property damage,
and will void the manufacturer warranty.
Burner Fuel Filter
Drain any water which has accumulated in fuel filter and
clean or replace element as needed.
Heating Coil
Coil Descaling:
In hard water areas, scale buildup within
the heating coil will occur. Scale deposits will decrease
the water temperature rise and may eventually clog the
heating coil. Contact your local service center when
descaling is needed.
Coil Desooting:
Poor grades of fuel oil or inadequate
combustion air will cause heavy soot buildup on the
outside surface of the heating coil. These deposits will
insulate the coil. This will restrict the air flow through the
coil, further aggravating the soot buildup. Contact your
local service center when desooting is needed.