Microwave barrier
- 25 -
Configuring the transmitter
Complete the configuration of the transmitter first.
The factory default network address of the transmitter is ’1’.
Initiate communication between the device and the computer by clicking ’Start’. If successful, the
default settings of the transmitter parameters are then displayed in the ’Internal state’ section of
the screen accessed via the ’System’ tab.
The following information is displayed:
Software version (firmware version)
Module (type of connected device - ’Transmitter’)
Producer ID (serial number of the device)
Maximum range (maximal operating range)
Temperature (this function is only available on devices with firmware version 3.9T or later)
Power supply (voltage - this function is only available on devices with firmware version 3.9T or
later)
Delivered frames (current successfully delivered frames)
Failed frames (an increase of this parameter indicates a degradation of communication between
the computer and the device)
The network address of the connected device may be changed in the ’Network config’ section of
the screen after first clicking the ’Modify’ check-box.
The communication rate may also be changed, via the ’Rate’ field.
To activate the settings, click ’Apply’ - the device will then be addressable at the newly-specified