TECHNICAL SPECIFICATIONS
WIRING CHARTS
Specification
Value
Detection zone length
32.81-984 ft./10-300 m
Minimum required level of signal received at maximum length of the
detection zone
8 dB
Minimum detection zone height for a protected segment length of
984 ft./300 m
8.20 ft./2.5 m
Range of detection speeds
1.64 / 6.56 / 32.81 ft./s
0.5 / 2 / 10 m/s
Working supply voltage, V-DC
12-36 VDC
Maximum current required at the working supply voltage of
12V/24V/36V,
а) transmitter unit
b) receiver unit
128mA/61mA/56mA
170mA/85mA/ 56mA
Maximum operable time after the supply is switched on
12 s
Maximum recovery time of the stand-by system after notification of
an alarm
10 s
Parameters of signal, switched with the contacts of the output
circuit:
-
maximum current, constant or alternate
-
maximum amplitude voltage
30 mA
72 V
Relay contact signal parameters:
-
maximum input resistance of the circuit
-
impulse voltage
-
maximum impulse duration
5 kΩ
10-30 V
0.5 s
Minimum signal duration
5 s
Operating frequency
24.001-24.250 GHz
Overall dimensions of
unit with bracket:
3.9x9.1x7.1 in./
100x230x180 mm
Maximum weight of the packaged detector
4 Lbs./1.8 kg
Minimum average service life of the detector, years (warrantied)
2