11
Working in Manual mode:
In Manual mode the 884G self-leveling mechanism is disabled
and the laser beams can be set at any slope required.
While the manual mode is engaged, the buttons are disabled.
1. Choose the needed laser beams.
2. If required, engage the pulse mode to work with detector.
3. To activate the manual mode, press and hold the Pulse mode
button (c) for 5 seconds, until the leveling indicator (e) will start
to blink fast. The leveling indicator (e) will continue to blink fast
to let you know that the beam is not leveled.
4. To mark a slope, tilt the laser to the desired angle.
5. To return to self-leveling mode, press and hold the Pulse mode
button (c) for 5 seconds, until the leveling indicator (e) will start
to blink slowly. Now that the laser level is working regularly, the
buttons enabled, you may choose another beam or engage /
disengage the pulse mode.