Wiring
P345MTR models have twelve terminals as noted in
Table 3
. The terminal strip is
removable for easy installation and wiring. When attaching wires to the connector,
strip off only the minimum insulation required (approx. 1/8'') and push the wire into
the connector until the insulation is flush or inside the connector body. This is
particularly critical for outdoor readers. While the reader itself is designed and
protected to IP65 standards, the cable wires can potentially corrode and short
together if not carefully mounted and tightly fastened in the connector body.
Table 3: Connector Pins
Table 4
indicates maximum wiring distances per Wiegand standard with the three
most common gauges of cable.
Table 4: Maximum Cable Distance per Wire Gauge
Pin
Description
Pin
Description
1
Buzzer
7
External Green LED Control
2
Ground
8
External Red LED Control
3
Power (9.4 to 16 VDC)
9
A - RS-485 - Used for Flash Upgrade
4
D1 Wiegand
10
B - RS-485 - Used for Flash Upgrade
5
D0 Wiegand
11
Tamper (Normally Closed)
6
Reserved for Future Use
12
Tamper (Normally Closed)
Wire Gauge
18 AWG
20AWG
22 AWG
Cable Distance
500 feet
(152 meters)
300 feet
(91 meters)
200 feet
(61 meters)