background image

Installation Manual

P600 ioProx Long Range Proximity Reader

8

DN5084-0804

1.2 Operations

At power-up the P600 emits beeps and flashes the LED. The number of beeps and flashes depends 
on the dipswitch mode selection, Kantech XSF or Wiegand. If the reader is set to 26-bit Wiegand, 
it sounds four beeps and the LED flashes three times. If it is set to Kantech XSF format, it sounds 
two beeps and the LED flashes two times. 

When a card is presented, the reader evaluates the card ID for a standard Kantech format. If the 
card is valid, the data are sent to the controller for user identification and a beep is heard while the 
LED turns solid green for a minimum of 1/4 second (extended duration depends on the controller 
setting). If permission is granted, the door unlocks. The next card can be read only after the 
current card is moved out of the field (36 inches minimum from the reader) for a period of at least 
one second. 

Note

The best read range is achieved with P10SHL cards; there will be a reduced read range 
with P20DYE, P30DMG and P40KEY cards.

Содержание ioProx P600

Страница 1: ...DN5084 0804 P600 ioProx Long Range Proximity Reader Installation Manual ...

Страница 2: ...Copyright 2008 Tyco International Ltd and its Respective Companies All Rights Reserved All specifications were current as of publication date and are subject to change without notice ...

Страница 3: ...ED In European Union countries it shall meet the applicable requirements of the Low Voltage Directive and protected as per the EN60950 Standard In all other countries it shall be of an approved type acceptable to the local authorities If during the installation OPENINGS are made in the PLASTIC ENCLOSURE it is the installer s responsibility to ensure that the same degree of protection for the ENCLO...

Страница 4: ...ons may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorien...

Страница 5: ...lief and Connecting Cables 11 Mounting the P600 13 Installing the P600 on a Wall 14 Installing the P600 on an Electrical Box 14 Installing the P600 on an Electrical Post 14 Installing the P600 on a Gooseneck 15 Weatherproofing the P600 16 Wiring the P600 17 Wiring 17 Closing the Enclosure 18 Applying the Power 18 Testing 19 Installation Notes and Guidelines 21 Power Supply 21 Installation Near Met...

Страница 6: ...Installation Manual P600 ioProx Long Range Reader vi DN5084 0804 ...

Страница 7: ...down the post on the lever of the switch 1 1 Specifications Typical read range Up to 29 73 cm Input voltage 12 to 28 VDC Maximum peak current 1A Dimensions H x W x D in 11 25 x 11 25 x 1 25 Dimensions H x W x D cm 28 5 x 28 5 x 3 15 Color Black Transmit frequency 125 KHz LED indicator Bicolor red and green Piezo buzzer Integrated Tamper switch Integrated normally closed when secured Operating temp...

Страница 8: ...hen a card is presented the reader evaluates the card ID for a standard Kantech format If the card is valid the data are sent to the controller for user identification and a beep is heard while the LED turns solid green for a minimum of 1 4 second extended duration depends on the controller setting If permission is granted the door unlocks The next card can be read only after the current card is m...

Страница 9: ... the enclosure 2 Setting the required data format Kantech XSF or 26 bit Wiegand 3 Installing the strain relief and connecting the cable 4 Mounting the reader to its location 5 Closing the enclosure 6 Powering up the power supply and the host 12 or 24VDC 7 Verifying the reading with a transponder card 2 1 Opening the Enclosure It is easy to open and close the enclosure Three sets of attachments all...

Страница 10: ... hinges 2 2 Setting the Data Format Most of Wiegand interfaces use standard 26 bit data formats compatible with various controller brands The Kantech Extended Secure Format XSF is proprietary and is supported by Kantech controllers only Using the Kantech XSF provides increased security and guarantees against duplication of cards The Kantech XSF is the default format To set the data format 1 To sel...

Страница 11: ...able length To install the strain relief and to connect cables 1 Install the strain relief on the rear of the P600 nut inside 2 Feed the cable through the strain relief 3 Connect the wires to the terminal strip with the minimum length necessary without leaving extra loops of wire inside the reader housing 4 Tighten the strain relief to secure the cable Note Before closing the cover refer to Weathe...

Страница 12: ...Installation Manual P600 ioProx Long Range Proximity Reader 12 DN5084 0804 ...

Страница 13: ...h type of installation No drilling is required for most installation types except for installation on an electrical post refer to Installing the P600 on an Electrical Post on page 14 Use the appropriate holes for the selected type of installation Wall mounting Post mounting Gooseneck mounting The following figure shows the location of all available installation holes Figure 3 1 Mounting Holes Note...

Страница 14: ...s 3 2 Installing the P600 on an Electrical Box For electrical box installation there are 11 holes to satisfy the North American single and double gang box and the European single gang box Refer to Figure 3 1 for the 11 B hole positions 3 3 Installing the P600 on an Electrical Post Two U bolts allow for installation on an electrical post There are four oblong mounting areas two per U bolts to accom...

Страница 15: ... meet the inside case room Figure 3 2 Electrical post mounting 3 4 Installing the P600 on a Gooseneck The gooseneck installation provides 4 mounting holes to match the IPEX MH U 25 Part number 77961 post base The post base combined with the 90º post IPEX EE2590 Part number 69084 complete the gooseneck installation Note Use 3 16 4 75 mm diameter 6 38 mm max 19 mm long 1 3 15 cm max pan head screw w...

Страница 16: ...ures weatherproofing The P600 is a sealed equipment but some holes will be created at installation time giving openings allowing water to enter The installer must pay attention to all new openings To weatherproof the P600 1 Fill holes with silicone before tightening screws 2 Use the liquid tight strain relief and seal the nut with silicone prior to tightening it 3 Screw in the two screws while kee...

Страница 17: ...a P600 with any standard host and a KT PC4204 power supply 4 1 Wiring Perform the following steps to complete wiring 1 Install the KT PC4204 as per the recommendations Kantech Installation Instructions DN1246 Note that the KT PC4204 is strictly used as a power supply and no other equipment except the transformer and the battery should be connected to it Do not power it up yet 2 Install the host as...

Страница 18: ... dipswitch for the communication format required XSF ON WIEGAND26 OFF if not done already 10 Close the P600 enclosure 4 2 Closing the Enclosure To close the enclosure 1 Slide the cover from top to bottom over the installed base until the cover hinges fit into the base openings Figure 4 2 Closing the enclosure 2 Push the cover to the base until they snap together 3 Screw in the two screws while mai...

Страница 19: ...84 0804 19 4 4 Testing Test for read range with a valid Kantech proximity card P10 SHL It is important to understand that the Host must be configured in order to accept the data from the reader If the reader does not work properly refer to Troubleshooting on page 23 ...

Страница 20: ...Installation Manual P600 ioProx Long Range Proximity Reader 20 DN5084 0804 ...

Страница 21: ...ype of power supply may generate enough noise to be transmitted or conducted to the P600 This may interfere with the reception of a card signal as some switching power supplies are not suitable to provide adequate regulation to the P600 reader 5 2 Installation Near Metal The P600 generates a electromagnetic field on all sides of the reader Any metal that conducts electricity especially metal that ...

Страница 22: ...ces that receive RF signals The read range is affected by the amount interference noise in the area Common sources of RF interference are Power supplies Electrical and electronic equipment Some types of lightning Computers and monitors Motors and generators HVAC compressors If the read range is reduced Move the reader to a location known to be free of interference Test read range from the new loca...

Страница 23: ...om the reader 9 Is there ice buildup on the printed circuit or antenna posts If yes return the reader Reader has reduced read range 1 Is a linear voltage regulated power supply being used with a backup battery 12V 1 5A The use of switching power supplies is not recommended 2 Is the reader installed on a beam pole pedestal or other metallic material which could cause interference 3 Is there a compu...

Страница 24: ... controller s reader type XSF or Weigand 26 bits is properly pro grammed 3 Verify that the correct proximity card is being used P10SHL P20DMG P30DMG P40KEY 4 Verify that there is communication between the reader and the door controller Reader works intermittently 1 Is it working in a harsh environment such as machine shop or construction site 2 Is there ice buildup on the printed circuit or antenn...

Страница 25: ......

Страница 26: ...Fax 1 450 444 2029 www kantech com kantechsupport tycoint com Copyright 2008 Tyco International Ltd and its Respective Companies All Rights Reserved All specifications were current as of publication date and are subject to change without notice DN5084 0804 ...

Отзывы: