Installation Manual
P600 ioProx Long Range Proximity Reader
10
DN5084-0804
To open the enclosure:
1. Unscrew the two screws at the bottom of the reader.
Figure 2.1 - Opening the enclosure
2. Slightly open the cover from the bottom by gently prying it using a flat screwdriver at one of
the screw position until the snap releases.
3. With your hand, pull the cover until it gets slightly over the base and then push it from bot-
tom-up to release the top hinges.
2.2 Setting the Data Format
Most of Wiegand interfaces use standard 26-bit data formats compatible with various controller
brands.
The Kantech Extended Secure Format (XSF) is proprietary and is supported by Kantech
controllers only. Using the Kantech XSF provides increased security and guarantees against
duplication of cards
.
The Kantech XSF is the default format.
To set the data format:
1. To select the Kantech XSF format, set the communication mode dipswitch to XSF (lower
position, toward the board edge side).
2. To select the 26-bit Wiegand format, set the dipswitch to Wiegand26 (upper position, toward
the board components).
STEP 3
STEP 2
STEP 1
Содержание ioProx P600
Страница 1: ...DN5084 0804 P600 ioProx Long Range Proximity Reader Installation Manual ...
Страница 6: ...Installation Manual P600 ioProx Long Range Reader vi DN5084 0804 ...
Страница 12: ...Installation Manual P600 ioProx Long Range Proximity Reader 12 DN5084 0804 ...
Страница 20: ...Installation Manual P600 ioProx Long Range Proximity Reader 20 DN5084 0804 ...
Страница 25: ......