4. How to Redisplay, Print and Delete Stored Data
27
SET
(8)
Move the cursor to
3. SET OK!
Press
SET
key.
△
,
▽
SET
(9)
Select the item to be output.
Then press
SET
key.
[Printing]
☆
To halt printing temporarily: Press
key
☆
To stop printing completely: Press
MENU
key
(10)
After printing, it will go back to the page setting screen.
☆
To continue printing, repeat the above procedure.
☆
To finish printing, press
MENU
key.
4.2.2 Printing Example
RESULT:Only calculation result is output.
DATA: Only measurement data is output.
ALL:
Both calculation result and
measurement data are output.
1. START P:005
2. END P:007
3
. SET OK!
< FORMAT >
1
. RESULT
2. DATA
3. ALL
<PRINT>
MEMORY
P:001~P:007
1. START P:001
2. END P:001
3
. SET OK!
Measurement Condition
(will be printed all the
time)
Calculation
Result
<RESULT>
Measurement
Data
<DATA>
<ALL>
[Average Mode]
2008.07.01 10:57
<AVE>
S-TIME(S) 01
DATA(N) 010
MEMORY
P001
VELOCITY
AVE: 2.58 m/s
MAX: 2.87 m/s
MIN: 1.89 m/s
TEMPERATURE
AVE: 126
°
C
MAX: 129
°
C
MIN: 123
°
C
No. VEL TEMP
(m/s) (
°
C)
1 2.37 126
2 2.83 126
3 2.47 125
4 1.89 124
[Interval Mode]
2008.07.01 10:57
<INT>
S-TIME(S) 01
DATA(N) 010
INT(min) 060
POINTS
024
MEMORY
P001
VELOCITY
AVE: 2.58 m/s
MAX: 2.87 m/s
MIN: 1.89 m/s
TEMPERATURE
AVE: 126
°
C
MAX: 129
°
C
MIN: 123
°
C
No. VEL TEMP
(m/s) (
°
C)
1 2.37 126
2 2.83 125
2008.07.01 10:57
<FLOW>
S-TIME(S) 01
DATA(N) 010
POINTS
016
AREA(m2) 0.100
MEMORY
P001
FLOW RATE
15.180 m3/min
910.80 m3/hour
VELOCITY
2.53 m/s
TEMPERATURE
126
°
C
No. VEL TEMP
(m/s) (
°
C)
1 2.37 126
2 2.83 126
3 2.47 125
[Air Flow Mode]
Содержание Anemomaster 6162