Chapter 5. Setting up a SMS Gateway
Variable
Value
Description
reconnect-delay
number
Optional the time between
attemps to connect an ESME to
an SMSC having failed to
connect initating or during an
SMPP session. The default is 10
seconds.
source-addr-ton
number
Optional, source address TON
setting for the link. (Defaults to
0).
source-addr-npi
number
Optional, source address NPI
setting for the link. (Defaults to
1).
source-addr-autodetect
boolean
Optional, if defined tries to scan
the source address and set TON
and NPI settings accordingly. If
you don’t want to autodetect the
source address, turn this off, by
setting it to no. (Defaults to yes).
dest-addr-ton
number
Optional, destination address
TON setting for the link.
(Defaults to 0).
dest-addr-npi
number
Optional, destination address
NPI setting for the link. (Defaults
to 1).