Chapter 5. Setting up a SMS Gateway
Variable
Value
Description
transceiver-mode
bool
Attempt to use a
TRANSCEIVER mode
connection to the SM-SC. It uses
the standard transmit ’port’, there
is no need to set ’receive-port’.
This is a SMPP 3.4 only feature
and will not work on an earlier
SM-SC. This will try a
bind_transceiver only and will
not attempt to fall back to doing
transmit and receive on the same
connection.
receive-port
port-number
The port number for the
RECEIVER connection to the
SMSC. May be the same as port.
Use value 0 to disable this I/O
thread.
smsc-username (m)
string
The ’username’ of the
Messaging Entity connecting to
the SM-SC. If the SM-SC
operator reports that the
"TELEPATH SYSTEM
MANAGER TERMINAL" view
"Control.Apps.View" value
"Name:" is
"SMPP_ZAPVMA_T" for the
transmitter and
"SMPP_ZAPVMA_R" for the
receiver the smsc-username value
is accordingly "SMPP_ZAP".
Note that this used to be called
system-id (the name in SMPP
documentation) and has been
changed to smsc-username to
make all Kannel SMS center
drivers use the same name.
smsc-password (m)
string
The password matching the
"smsc-username" your
teleoperator provided you with.
system-type (m)
string
Usually you can get away with
"VMA" which stands for Voice
Mail Activation.
38