Schedules

Section D

Lowering the room temperature setting reduces the amount of fuel required to heat 
the building resulting in energy savings.

This thermostat can follow a programmable schedule in order to automatically 
lower the room temperature setting. A schedule master such as a Timer 033e is 
required in order to gain programmable schedule functionality.
When operating on a programmable schedule, a   symbol is shown, as well as a 

 or a  . The   or   indicates the current operating temperature.

If a   symbol does not appear, there is no schedule available.

Display

Action

Occupied temperature. No schedule.

Unoccupied temperature. No schedule.

 

Programmable schedule at occupied temperature.

 

Programmable schedule at unoccupied temperature.

Scene

Display

Room Temperature Setting

1

 or 

 

 or 

 

Follows programmable schedule or 
operates at the occupied   temperature.

2

Away

Away temperature.

3

Unoccupied  

temperature.

Scenes (System Override)

Section E

When a programmable schedule is selected, there is a time delay for the temperature 
to change from the   temperature to the   temperature.

The thermostat uses Optimum Start to predict the heat up and cool off rate of 
the room. The optimum start feature allows the room to reach the set room   
temperature by the time set in the programmable schedule. This applies for both 
heating and cooling.

Scenes provide an easy way to save energy while away on vacation, or override a 
pre-set schedule when plans change. tekmarNet

®

 devices such as a User Switch 

480 or 481 provide scene adjustment. 

This thermostat responds to the following scenes:

While in the 

Away

 scene, the room temperature cannot be changed using the 

 or 

 buttons. Change the scene from 

Away

 to   or   to change the temperature.

Содержание tekmarNet 4

Страница 1: ...Outdoor temperature display Bright backlight 2 button temperature adjustment Communication with other tekmarNet devices improves system efficiency and comfort Schedule member status enables setback op...

Страница 2: ...iring 4 Testing the Thermostat Wiring 4 Mounting the Thermostat 5 Cleaning the Thermostat 6 Switch Settings 6 User Interface 7 Display 7 Button Operation 7 Symbols Description 7 Settings 8 14 Sequence...

Страница 3: ...wire is 150 m Strip wire to 10 mm for all terminal connections Use standard 4 conductor 0 75 or 1 0 mm2 flex cable Installation Location Removing The Thermostat Base Push tab 1 Remove thermostat from...

Страница 4: ...on the thermostat to the 1 L N and terminals on the Wiring Center 375x Connect the optional auxiliary sensor wires to the sensor terminals 5 and 6 1 2 3 4 Wiring Center 375x Slab Sensor 079e OR Outdo...

Страница 5: ...should appear on the display 6 There should be continuity between the L 3 and 4 terminals Testing the tekmarNet 4 Bus The symbol is shown on the display when communication is present If the thermosta...

Страница 6: ...s not follow a programmable setback schedule 2 ON SCENE The thermostat responds to changes in the scene system wide manual overrides Requires the installation of a User Switch 480 or 481 to use this f...

Страница 7: ...ROUP The cooling group is cooling Heating can start once the cooling is finished LOCK Locked to User access level CLOCK Operating on a programmable schedule tekmarNet Communication is present WARNING...

Страница 8: ...ller SET ROOM HEAT AWAY Set the room heating temperature while in the Away scene Continued on next page Press and hold down both the and buttons for 2 seconds to change from one step to the next Relea...

Страница 9: ...ing in the Adjust menu is set to Off 40 to 122 F 4 5 to 50 0 C Default 65 F 18 5 C Installer User SET FLOOR HEAT Set the floor heating temperature while in the event Available when A slab sensor is in...

Страница 10: ...rge number with Software Version upper right corner and the thermostat address 40 to 95 F 4 5 to 35 0 C Default 85 F 29 5 C Installer MAXIMUM SET ROOM HEAT Set the maximum room heating limit while in...

Страница 11: ...On AND A slab sensor is installed on the auxiliary sensor input AND Sensor setting in the Adjust menu is set to Floor Off 40 to 122 F Off 4 5 to 50 0 C Default Off Installer User SET FLOOR MINIMUM Set...

Страница 12: ...slab sensor is installed on the auxiliary sensor input AND Sensor setting in the Adjust menu is set to Floor 1 2 3 4 Default 1 Installer SCHEDULE Thermostat can follow schedule master 1 2 3 or 4 Avail...

Страница 13: ...ult Sychronize Installer HEAT CYCLES PER HOUR Select either Auto cycle or Synchronize with other thermostats on the tekmarNet system Choose Synchronize when zone heated using a boiler Choose Auto when...

Страница 14: ...tekmarNet ADDRESS The address is shown in the large number field Auto is shown in the upper number field when using automatic addressing Press the or the button to manually select an address The addre...

Страница 15: ...n on the display when the thermostat is heating The heat can cycle on and off within 1 C of the Set Room Heat temperature Freeze Protection The thermostat operates the heat whenever the room or floor...

Страница 16: ...tion Section B In order to prevent heating and cooling at the same time this thermostat can operate together with other thermostats on a tN4 system to form a cool group In a cool group one thermostat...

Страница 17: ...isplay Room Temperature Setting 1 or or Follows programmable schedule or operates at the occupied temperature 2 Away Away temperature 3 Unoccupied temperature Scenes System Override Section E When a p...

Страница 18: ...settings have been reviewed BUS ERROR The tekmarNet 4 communication bus has either an open or a short circuit The result is that there are no communications Check for loose wires Check for short circu...

Страница 19: ...t circuit error This error cannot be field repaired Contact your wholesaler or kanmor sales representative for details on repair procedures ROOM SENSOR OPEN CIRCUIT The built in air temperature sensor...

Страница 20: ...intentionally removed locate the Room Sensor setting in the Adjust menu and set to On Power the thermostat down and up to clear the error OUTDOOR SENSOR SHORT CIRCUIT The auxiliary outdoor sensor has...

Страница 21: ...clears after the auxiliary room sensor fault is corrected AUXILIARY ROOM SENSOR OPEN CIRCUIT The auxiliary room sensor has an open circuit Check for loose or damaged wires Locate and repair the proble...

Страница 22: ...early so that the room is comfortable at the scheduled time Pressing button does not increase temperature Flashing Max Installer can increase the Maximum Set Room Heat Flashing Floor Max Floor tempera...

Страница 23: ..._____________________ Thermostat Location _____________________________________________ Technical Data tekmarNet 4 Thermostat 538e One Stage Heat Packaged weight 380 g Enclosure NEMA 1 white PVC plast...

Страница 24: ...rts or labor to remove or transport the defective Product or to reinstall the repaired or replacement Product all such costs and expenses being subject to Purchaser s agreement and warranty with its c...

Отзывы: