6. Error Codes
Error Code
#
Error
Message
Description & Recommended Solution
201
Bad Master
Description:
The Copy process failed due to a read error which occurred on
the Source device.
Possible Solution:
Check the Source device by running the “Verify Source”
function. If the device does not pass the “Verify Source” check,
try duplicating using a different Source device.
202
No Device
Found
Description:
The duplicator does not detect any Target devices connected.
Possible Solution:
Remove and then reconnect the Target devices. Make sure that
the Green LED indicator is lit next to each Target device before
starting the duplication process.
203
Source
Removed
Description:
The Asynchronous Copy process failed because the Source
device is not detected.
Possible Solution:
Remove and then reconnect the Source device. Make sure that
the Green LED indicator is lit next to the Source device before
starting the duplication process.
206
Targets &
Master Size
Mismatch!
Description:
The Target devices are smaller in capacity than the Source
device.
Possible Solution:
Target devices have to be equal or greater in capacity than the
Source. If the capacity on the Source and Targets are listed as
being identical, please enable the “Size Tolerance” option in the
Setup menu.
260
No Update File
Description:
During the Update Firmware process, the duplicator was not
able to locate a firmware update file.
Possible Solution:
Confirm that the USB device containing the firmware update
file is formatted FAT32. Also confirm that the firmware update
file is not a “.zip” or “.rar” file. If it is, please extract it and
transfer the extracted files to the USB device.