10
Before First Use
1.6 before First Use
1. Place the Kanguru Clone Tower Duplicator where there is proper ventilation. Avoid using the
Kanguru Clone in environments with high temperatures.
2. Before plugging in the AC Power Cable, please make sure that the voltage adjustment switch is
set to your local voltage 110V/220V. The voltage adjustment switch is located on the back of
the unit, above the power cable connection.
Note:
Make sure that sufficient power is supplied to the Kanguru Clone. Incorrect power will
cause faulty operation. It is highly recommended that you connect your Kanguru Clone using a
UPS (uninterruptible power supply).
3. You are now ready to begin using your Kanguru Clone. To begin, turn on the unit by pushing
the power button.
Things to remember
•
Make sure that sufficient power is supplied to the Kanguru Clone. Incorrect power will cause
faulty operation. It is highly recommended that you use a UPS (uninterruptible power supply)
with the Kanguru Clone.
•
The Kanguru Clone supplies power to all drives during a cloning session. There is no need to
connect an external power source to the drives. The unit can supply up to 1.5A at 12V and up to
1A at 5V to each drive.
•
It is OK to connect and disconnect Master or Target drives while the Kanguru Clone is powered
on. However, do NOT connect or disconnect drives while any operation is running on the drive
or if duplication is in progress.
•
The Kanguru Clone Tower has a total of six bays where you can insert hard drives.
○
Master drives should be inserted in the Source bay located at the top and labeled ‘
S
’.
○
Target drives can be inserted into any bay below the Source
•
Insert all Master and Target hard drives before you execute an operation.
•
CaUTIoN!
Disks may be hot when removing them from the hard drive duplicator. It is
recommended that you wait a minute before removing drives post duplication.