- 11 -
4.3 Main
Displays
The main display can be changed to show either 4 or 8 parameters at one time. Two options
are available when 4 parameters are selected.
•
4 Page Mode
displays 4 lines of data in set format, each page is predefined.
•
Line scroll mode
allows you to customise the display to show the data you require.
•
8 Page Mode
displays 8 parameters on 4 lines in set format, the bottom two can be
changed.
Changing between the different modes is detailed in
Display Menu Section 5.2.4
.
4.3.1 4 Page Mode
Use the and keys to change the information that is displayed on the screen. The
following pages are available.
NATURAL GAS
DATE
. . .
07-08-96
TIME
. . .
12:31:35
BATTERY %
. .
54
NETT C
. . .
0.0
O2 %
. . .
20.9
CO ppm
. .
0000
EFF (G) %
. . .
0.0
CO2 %
. . .
0.0
FLUE C
. . .
0.0
INLT
NOT FITTED
AMBIENT C
. . .
21
CO/CO2 R
. .
0.0001
P INDEX %
. . .
0.01
XAIR %
. . .
0.0
Prs mbar
0.00
This screen only displayed on an
analyser fitted with an NO sensor
NO ppm
. .
0000
NOx ppm
. .
0000
NOx calc%
. . .
5
O2 ref %
. . .
3.0
TIP -
In 4 page mode only turns the backlight ON and OFF.