The ‘Tip-light’ is used to see around the area of the 
leak when in a dark environment. 

 
6. 

When this instrument is used in noisy environments, 
look at the red LED which flashes more rapidly as the 
tic rate increases. The optional earphone can be 
plugged into the unit’s side if there is high 
background noise or the operator does not want to 
disturb other people.  This also disables the speaker.   

 
7. 

If the tic rate becomes uncontrollable, it may be 
necessary to change the sensor. 

 

8. 

The detector will respond to some leak finding 
solution (e.g. Soap), so please use your detector first.  
If over exposed to some gases, the detector may take 
an extended period of time to return to normal. 

 

 

Battery Replacement

 

     

       

1. 

Remove the battery case cover. 

 
2. 

Replace the 9V alkaline battery.  An alkaline battery 
should always be used. Ensure the polarity of the 
battery matches that shown in the compartment. 

 
3. 

Replace battery case cover.

 

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание CD100A

Страница 1: ...S DETECTOR Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Tel 01707 375550 Fax 01707 393277 Stock No 17444 2 June 2004 Downloaded from Elcodis com electronic c...

Страница 2: ...r 4 Power On Light 5 Solid State semi conductor sensor 6 Sensor Cover 7 Audible Leak Indicator 8 Tic Adjustment located on the side of the unit 9 Protective Boot 10 Gooseneck Clip 11 Socket for Option...

Страница 3: ...e and toxic gases A partial list of these gases include Acetone Jet Fuel Alcohol Lacquer Thinners Ammonia Methane Benzene Naphtha Butane Natural Gas Ethylene Propane Gasoline Petrol Toluene Hydrogen I...

Страница 4: ...The red LED indicator will flash in correspondence with the tic rate Please allow around 10 seconds for the sensor to stabilise indicated by a steady tic rate However it may occasionally require up t...

Страница 5: ...speaker 7 If the tic rate becomes uncontrollable it may be necessary to change the sensor 8 The detector will respond to some leak finding solution e g Soap so please use your detector first If over...

Страница 6: ...ss of the standards defined in the Directive there may be occasions where it would be appropriate to check the analyser prior to use The following procedure should be adopted Go through the normal sta...

Страница 7: ...top half of the sensor housing Pushing to one side aids removal 3 With care move the Tip light LED to one side to gain access to the sensor small silver can 4 Unplug the sensor and replace it with a...

Страница 8: ...conds Response Time Instantaneous Duty Cycle Continuous Battery Life 5 hours typical use Dimensions 8 H x 4 W x 1 5 D 205mm x 100mm x 36mm Weight 15 oz 460 gm Probe Length 18 inches 460 mm Operative 0...

Страница 9: ...61000 6 1 and is certified to be compliant Specification EC EMC KI CD100A details the specific test configuration performance and conditions of use Please Note Batteries used in this instrument should...

Отзывы: