The monitor is measuring temperature outside its 
measurement range. 
 

 

 

These are displayed when it is necessary to reset the 
monitor.  To reset, switch off the monitor, remove its 
batteries and wait for a minimum of one minute, 
reinsert batteries and switch on. If either error 
message remains please contact our Service 
Department for further assistance. 

 
 

ƒ

 

Warranty: 

12 months parts and labour. 

 

Содержание ALERT-CO2

Страница 1: ...KANE ALERT CO2 Monitor with Temperature Operating Instructions...

Страница 2: ...es Max Min mode records the maximum and minimum concentrations of CO2 since the monitor was switched on Alarm mode sounds at 1000 PPM the ASHRAE limit and can be turned off RCFS Mode recovers original...

Страница 3: ...ounder can be switched on or off OUTSIDE Modifies the outside CO2 concentration The factory nominal setting is 400 ppm CALI Allows trained service personnel to recalibrate the sensor Take care using t...

Страница 4: ...tabilizes and displays CO2 readings on its Upper Display which remain visible at all times Temp and Ventilation Rates Lower Display Use the Up Down button to scroll through Temperature and Ventilation...

Страница 5: ...presents how much air is introduced into the indoor space from the outside Low levels indicate low ventilation rates and potentially poor air quality High levels indicate excessive ventilation and pot...

Страница 6: ...s Enter to return to UserMode 6 MaxMin Mode Viewing Maximum and Minimum values The monitor s MaxMin Mode displays the maximum and minimum CO2 readings since the monitor was last switched on 6 1 Press...

Страница 7: ...ppm 5ppm from 1 000 2 000ppm 10ppm from 2 000 3 000ppm over 3000 ppm display shows Hi Accuracy 50 ppm or 5 of reading Repeatability 20 ppm Temperature Dependence 0 1 of reading per C or 2 ppm per C wh...

Страница 8: ...12 months Power Supply Battery type Alkaline 4 x AA cells give approx 80 hours operation External 6 VDC from external AC DC adapter supplied as standard Note charger is designed for indoor use only P...

Страница 9: ...n it is necessary to reset the monitor To reset switch off the monitor remove its batteries and wait for a minimum of one minute reinsert batteries and switch on If either error message remains please...

Страница 10: ...of disturbance is acceptable If not acceptable adjust the analyser s position to minimize interference or switch off if possible the offending equipment during your test At the time of writing this ma...

Страница 11: ...ration APPENDIX Recommended Carbon Dioxide Levels British Standards BS6896 BS6230 and BS5990 confirm CO2 concentration should not exceed 2800ppm where people are working HSE Regulation EH40 sets the m...

Страница 12: ...Thank you for buying this instrument...

Страница 13: ...l 41 41 541 5877 Fax 41 41 541 5878 Email General Information Sales info kesn ch Accounts Department accounts kesn ch USA O ce 233 Rogue River Highway 425 Grants Pass Oregon 97527 5429 USA Tel 1 503 2...

Отзывы: