Before starting the generator, connect the ground wire to the ground
!
!
IMPORTANT!
12. BEFORE STARTING
12.1. CHECK THE FUEL LEVEL
1. Please wear protective gloves to avoid getting gasoline on the skin.
2. Remove the fuel tank cap and check the fuel level
3. Add fuel to the filter level if necessary
4. Screw the fuel tank cap back tightly
pic 8
pic 9
12.2. CHECK THE OIL LEVEL
1. Please wear protective gloves to avoid getting oil
on the skin.
2. Unscrew the oil level gage and clean it with clean
cloth.
3. Put the oil gage back without screwing it.
4. Take the oil level gage out and check the oil level
according to the mark on a gage.
5. Add oil if it’s level is below the mark on a gage.
6. Screw the oil gage back.
Only unleaded gasoline is recommended for the generator.
The use of other fuels could cause engine damage.
!
!
IMPORTANT!
!
!
IMPORTANT!
If the generator has not been used for a long time, try charging the
battery with the battery charger (not included).
FILL TO
HERE
Fuel tank cap
Fuel filter
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE
FOLLOWING REQUIREMENTS SHOULD BE MET:
1. During commissioning, do not connect power consumers, the power of which
exceeds 50% of the nominal (operating) power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain
oil while the engine is still hot after operation to ensure quick and complete oil
draining.
3. Check and clean the air filter, fuel filter and spark plug.