background image

20

WARRANTY SERVICE TERMS

TERMS AND CONDITIONS:

The international manufacturer warranty is 1 year. The warranty period starts from the date of 

purchase. In cases when warranty period is longer than 1 year according to local legislation please 

contact your local dealer. The Seller which sells the product is responsible for granting the warranty. 

Please contact the Seller for warranty. Within the warranty period, if the product fails because of 

defects in the production process, it will be exchanged on the same product or repaired.

The warranty card should be kept throughout the warranty period. In case of warranty card loss, 

a second one will not be provided. The customer must provide the warranty card and buyer`s check 

during request for repair or exchange. Otherwise, the warranty service will not be provided. The 

warranty card, attached to the product during sale, should be correctly and fully completed by the 

retailer and customer, signed and stamped. In other cases, warranty is not considered as valid.

Provide clean product to the service center.  Parts, that must be replaced, are the property of the service 

center.

WARRANTY DOES NOT COVER:

- If the user has failed to comply with the instructions in this manual.
- If the product features damaged or missing identification stickers or labels, serial numbers, etc. 
- If product malfunction was due to improper transportation, storage and maintenance.
- In case of mechanical damages (cracks, chips, impact and fall marks, deformation of housing, 

power cord, plug or any other components), including those resulting from the freezing of water (ice 

formation), provided there are foreign objects inside the unit.

- If the product has been improperly installed and connected to the mains supply or misused.
- If the claimed malfunction cannot be diagnosed or demonstrated.
- If proper operation of the product can be restored following cleaning from dust and dirt, 

appropriate adjustment, maintenance, oil change, etc.  

- If the product is used for business related purposes.
- If faults are detected, which have been caused by product overload. Signs of overload are molten 

or discolored parts as a result of high temperatures, damaged cylinder or piston surfaces, degraded 

piston rings or connecting rod bushes.

- The warranty does not cover the failure of the product automatic voltage regulator due to careless 

handling or mishandling.

- If faults are detected, which have been caused by instability of the user’s power grid.
- If there are faults caused by contamination or fouling such as contamination of the fuel, oil or 

cooling system.

- If electrical cables or plugs show signs of mechanical or thermal damage.
- In the event of foreign liquids and objects, metal chips, etc. inside the product. 
- If the malfunction is caused by the use of non-original spare parts and materials, oils, etc.
- If there are two or more faulty units that are not interconnected.
- If the damage was caused by natural factors such as dirt, dust, humidity, high or low temperature, 

natural disasters.

- To quick-wear parts and components (spark plugs, nozzles, pulleys, filter and safety elements, 

batteries, removable devices, belts, rubber seals, clutch springs, axles, manual starters, oils, gear).

- To preventive maintenance (cleaning, greasing, washing), installation and adjustment. 
- If the product was tampered with, independently repaired or modified. 
- In case of malfunctions resulting from normal wear and tear as a result of long-term use (end of 

life).

- If product operation was not stopped and continued after detecting a malfunction.
- Batteries supplied with equipment are covered by a warranty of three months.

Содержание KSB 6000D

Страница 1: ...ENG Diesel Generator Silent Diesel Generator KSB 6000D KSB 6000DE KSB 8000DE ATSR KSB 8000DE 3 KSB 6000DES Please read this manual carefully before use OWNER S MANUAL...

Страница 2: ...ded oils _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _17 12 Air filter maintenance _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _18 13 Fuel filter technical maintenance _ _ _ _____________19 14 Accumulator ma...

Страница 3: ...nd photos of the product may vary from its actual appearance At the end of this manual You may find contact information which you are free to use in case of any issues occurrence Alldata specifiedinth...

Страница 4: ...n working with power cables Immediately replace it in case of damage as damaged wire increases the risk of electric shock All connecting the generator to the network must be made by certified electric...

Страница 5: ...operating make sure that the generator is on a flat level surface and the engine switch is set to Off Keep the generator dry well ventilated place if you are not using it Check the connection of movi...

Страница 6: ...urring obligation The pictures in this manual are schematical and may not match the parameters of original product IMPORTANT 1 9 2 3 5 4 8 6 7 1 Reinforced steel frame 2 Fuel tank cap 3 Air filter 4 A...

Страница 7: ...1 65 1 65 1 65 1 65 Enginecylindervolumecm3 406 406 406 455 455 Power output controller AVR AVR AVR AVR AVR Engine start electric manual manual electric manual electric manual electric Power factor c...

Страница 8: ...currents when choosing a generator Most electric tools have starting current ratio 2 3 This means that when you turn such tools required generator power have 2 3 times more power load The biggest fac...

Страница 9: ...ENANCE PANEL Pic 3 1 Engine start 2 Oil level indicator 3 Voltmeter or LED display V voltage Hz frequency T1 current time since the last start T2 total time since the commissioning for KSB 6000DES ATS...

Страница 10: ...which is under decompressor lever Pic 5 push the decompressor at the top of cylinder head to reducepressureinthecylinderandreliefextension Vigorouslypullstarterhandleandstarttheengine Do not let a sha...

Страница 11: ...tthepositiveterminalofthebattery TurnthemotorsafetyswitchtoONposition SetthekeytoONposition TurnthekeyclockwisetoSTARTposition After the engine launch release the key and it will automatically return...

Страница 12: ...ernator to be cooled 3 Incaseofmanualstart settheengineswitchtoOFFposition 4 Incaseofelectricstart turnthekeytoOFFposition 5 For all types of diesel generators there is an emergency stop lever for the...

Страница 13: ...ormance of regular maintenance works the manufacturer bears no responsibility for such damages Such damages are also Damages occurred as a result of using non original spare parts Corrosion damages an...

Страница 14: ...rformance characteristics and is a major attribute defining its service life Use oils designed for four stroke cycle vehicle engines sincesuchoilscontaincleaningadditives whichcomplyorevenexceed SE st...

Страница 15: ...is set on flat level surface 2 Place a drain oil holding tank under the engine 3 Turn the drain cap located under the oil depth gage cap in the engine by means of a 10mm hexagon spanner 4 Wait till th...

Страница 16: ...time to time and clean any contaminations Regular air filter maintenance is necessary to maintain sufficient carburetorairinflow Theairfiltershouldbecleanedmoreoftenwhen using generator in dusty condi...

Страница 17: ...fueltocleanthefilter 4 Putthefilterbacktothefueltank Thefuelfilterinthefuelsupplypipeline Thisfilterhastobereplacedevery100operatinghours It slocatedunderthefueltank onthefuelhosethroughwhichfuelenter...

Страница 18: ...al starter until you feel light resistance so that the intake and exhaust valves are closed Remove the negative terminal of the battery for the electric start models Clean generator from dirt and dust...

Страница 19: ...dirty Clean the cooling fins Air filter is dirty Clean the air filter No voltage while engine is working Circuit breaker is active Turn on the circuit breaker Connected cables are corrupted Check the...

Страница 20: ...adio 50 250 TV set 100 400 Refrigerator 100 150 Oven 1000 2000 Freezer 100 400 Drill 400 800 Hammer drill 600 1400 Grinding machine 300 1100 Circular saw 750 1600 Electro planer 400 1000 Electro jigsa...

Страница 21: ...y installed and connected to the mains supply or misused If the claimed malfunction cannot be diagnosed or demonstrated If proper operation of the product can be restored following cleaning from dust...