RECOMMENDED OILS
9
Upon oil level decrease it is necessary to add the required quantity in order to provide the correct generator opera
-
tion. It is necessary to check the oil levels according to technical maintanance schedule.The detailed description of oil
filling and draining can be found in the full version of the manual.
Use oils designed for four-stroke cycle vehicle engines
SAE10W-30, SAE10W-40. Motor oils with other viscosity levels,
may be used only if the average air temperature in your region
does not exceed the limits of the temperature range, specified
in the table.
0
00
CC
10W-30, 10W-40
40
40
30
30
20
20
10
10
-10
-10
-20
-20
AIR FILTER TECHNICAL MAINTENANCE
10
Air filter cleaning is to be performed each 50 hours of the generator operation (every 10 hours in unusually dusty
conditions).
CLEANING THE FILTER:
CLEANING THE FILTER:
1. Open the clips on the upper cap of the air filter.
2. Remove the sponge filtering element.
3. Remove all dirt deposits inside the hollow case
of the air filter.
4. Thoroughly wash the filtering element in warmsoapy
water.
5. Dry the sponge filter.
6. Dry filtering element is to be moistened by
machine oil and excess oil is to be squeezed out.
SPARK PLUGS TECHNICAL MAINTENANCE
11
DAMPER AND FLAME ARRESTER
MAINTENANCE
12
Spark plug has to be intact, without soot deposits and to have a correct gap.
SPARK PLUG VERIFICATION:
SPARK PLUG VERIFICATION:
1. Remove the cap from the spark plug.
2. Remove the spark plug by means of a corresponding spanner.
3. Examine the spark plug. If is is shattered – it is necessary to replace it.
Recommended replacement spark plugs – F7TC.
4. Measure the gap. It has to be within range 0.7-0.8 mm.
5. In case of repeated use, the spark plug has to be cleaned by means of a metal brush.
After that – set the correct gap.
The engine and damper will get very hot after the generator has been started. Do not touch the engine or damper
with any part of your body or clothing during inspection or repair until they have cooled down.
Remove the screws and then pull the protective cover towards you. Loosen the bolts and remove the cover, screen
and flame arrester of the damper. Descale the screen and flame arrester of the damper with a wire brush.Inspect
the screen and flame arrester of the damper. Replace them if they are damaged. Replace the flame arrester. Replace
the screen and cover of the damper. Replace the cover and tighten the screws.
Match the protrusion of the flame arrester to the hole in the
pipe damper.
IMPORTANT!
www.ks-power.de/en
|
8
Содержание KS 1200i
Страница 1: ...Please read this manual carefully before use OWNER S MANUAL Inverter Generator KS 1200i EN...