SPECIFICATIONS

3

Model

KS 1200i

 

Voltage, V

230

Maximum power, kW

1.2

Nominal power, kW

1.0

Frequency, Hz

50

Current, A (max.)

5.22

Outlets

1х16А

Engine start

Manual

Fuel tank volume, l

3.5

Operating time at 50% load, h

5.5

Noise level Lpa (7m)/Lwa, dB

67/92

Output 12V, A

5.0

Engine model

KS 110і

Engine type

Gasoline powered one-cylinder, four-stroke

Engine power, hp

2.0

Crankcase volume, l

0.4

Engine volume, cm

3

87

Power output controller

AVR

Power factor, cos φ

1

Net dimensions (L*W*H), mm

310*310*380

Gross dimensions (L*W*H), mm

335*330*415

Net weight, kg

13

Protection class

IP23M

Nominal voltage tolerance – max. 5%

To ensure reliability and increase the engine service life, peak powers may be slightly limited by circuit breakers.

The optimal operating conditions are ambient temperature of 17-25°C, barometric pressure of 0.1 MPa (760 mm Hg), 

and relative humidity of 50-60%. Under these environmental conditions, the generator can provide maximum perfor-

mance in terms of the declared specifications.

In the event of deviations from these environmental indicators, the generator performance may vary.
Please note that in order to preserve the long service life of the generator, continuous loads of more than 80% of the 

nominal power are not recommended.

www.ks-power.de/en

   

|

    3

Содержание KS 1200i

Страница 1: ...Please read this manual carefully before use OWNER S MANUAL Inverter Generator KS 1200i EN...

Страница 2: ...at a minimum distance of 1 m Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We care about the environment therefore we consider it expedient to save p...

Страница 3: ...pressor or submersible pump IMPORTANT General view of inverter generators description of control panels s General view of inverter generators description of control panels safety symbols and descripti...

Страница 4: ...415 Net weight kg 13 Protection class IP23M Nominal voltage tolerance max 5 To ensure reliability and increase the engine service life peak powers may be slightly limited by circuit breakers Theoptim...

Страница 5: ...r Improper operation of the cooler can cause damage to the motor inverter or alternator IMPORTANT ENGINE SWITCH ENGINE SWITCH To start the engine turn the engine switch to the ON position To turn off...

Страница 6: ...air intake valve on the fuel tank cap Recommended fuel Recommended fuel unleaded gasoline Fuel tank volume Fuel tank volume see specifications table CHECK BEFORE GETTING STARTED 6 If the DC fuse turns...

Страница 7: ...load allow the engine to run for 1 2 minutes to warm it up When disconnecting the load after lengthy operation do not turn off the generator Allow the generator to run idle for 1 2 minutes so that it...

Страница 8: ...often operates at high temperature or high load the oil should be replaced every 25 operating hours If the engine often runs in dusty or other harsh conditions clean the air filter every 10 operating...

Страница 9: ...d excess oil is to be squeezed out SPARK PLUGS TECHNICAL MAINTENANCE 11 DAMPER AND FLAME ARRESTER MAINTENANCE 12 Spark plug has to be intact without soot deposits and to have a correct gap SPARK PLUG...

Страница 10: ...methods as well as average device capacities can be found in the full version of the manual of the manual The international manufacturer warranty is 1 year The warranty period starts from the date of...

Страница 11: ......

Страница 12: ...www ks power de info dimaxgroup de Polska DIMAX International Poland Sp z o o Polen Warczawska 306B 05 082 Stare Babice www ks power pl info pl dimaxgroup de 47 02222 www ks power com ua sales ks pow...

Отзывы: