background image

ACD200 Usermanual                                            Functioanl Parameter List 

- 15 - 

Hd.05 

Fault record before 

Hd.04 

Fault record before Hd.04 

E0H 

Hd.06 

The rated frequency 

when the latest 

fault happened  

The rated frequency when the latest fault 

happened 

0.1Hz 

E1H 

Hd.07 

The rated output 

frequency when the 

latest fault 

happened 

The rated output frequency when the latest 

fault happened 

0.1Hz 

E2H 

Hd.08 

The rated output 
current when the 

latest fault 

happened 

The rated output current when the latest 

fault happened 

0.1A 

E3H 

Hd.09 

The rated output 

voltage 

when the latest 

fault happened 

The rated output voltage 

when the latest fault happened 

1V 

E4H 

Hd.10 

The rated DC bus 

voltage  

when the latest 

fault happened 

The rated DC bus voltage  

when the latest fault happened 

1V 

E5H 

HE

HE

HE

HE-

--

- Secret Code and Manufacturer Functional Parameters

 Secret Code and Manufacturer Functional Parameters

 Secret Code and Manufacturer Functional Parameters

 Secret Code and Manufacturer Functional Parameters

 

  

 

HE.00 

User code 

0000-9999 

0000 

× 

EAH 

HF

HF

HF

HF-

--

-Monitoring Functional Parameters

Monitoring Functional Parameters

Monitoring Functional Parameters

Monitoring Functional Parameters

 

  

 

HF.00 

Rated frequency   Current rated frequency  

0.1HZ 

 

 

HF.01 

Output Frequency  Current output frequency  

0.1HZ 

 

 

HF.02 

Output current  

The effective value of present output  
fequency  

0.1A 

 

 

HF.03 

Output voltage 

he effective value of present output  
voltage 

1V 

 

 

HF.04 

DC bus voltage   Current DC bus voltage  

1V 

 

 

HF.05 

Load motor speed  

Equal to that the output frequency times the 
load motor speed correction factor  

1(r/m) 

 

 

HF.06 

Maodule tempreture IGBT radiator tempreture  

1℃ 

 

 

HF.08 

Analog input ACI  Analog input ACI value  

 

 

HF.09 

MI、FWD、REV input 

terminal  

Inout terminal status  

 

HF.10 

PID rated pressure rated pressure  

Mpa 

 

HF.11 

PID feedback 

pressure  

feedback pressure  

Mpa 

 

Содержание ACD200 Series

Страница 1: ......

Страница 2: ...lease make sure to cut off the power The electronic components in the inverter are sensitive to static so please do not put anything in the inverter and do not touch the main circuit board After cut o...

Страница 3: ...d Brake Parameters 5 H3 Auxiliary Fuctional Parameters 6 H4 Simple PLC Function Parameters 8 H5 Closed Loop Functional Parameters 9 H6 Termianl FUnction Parameters 10 H7 Specific Traverse Function Par...

Страница 4: ...FWD Forward Runing Order REV Reverse Turn forward and reversely switch value command refer to two wire and three wire control function in H6 08 Optical coupler isolation input Input impedance R 2K MI1...

Страница 5: ...epresent 11 kinds of unit please refer to the parameter description H6 17 the output voltage current is selected by J5 factory setting voltage reference GND Voltage output range 0 10V Carrent output r...

Страница 6: ...dress Address H0 00 Frequency Input Channel Selection 0 operation keypad digital setting 1 terminal UP DOWN adjust and set frequency memorize when power down or stop 2 terminal UP DOWN adjust and set...

Страница 7: ...eed Correction Factor 1 9999 1 100 0EH H0 15 V F Curve Setting 0 conatant torque curve 1 decreasing torque curve 1 2 nd power 2 decreasing torque curve 2 1 7 th power 3 decreasing torque curve 3 1 2th...

Страница 8: ...Maxi ACI rated 0 0 100 0 0 1 100 0 24H H1 08 Maxi ACI rated relative frequency 0 0 Upper Limit Frequency 0 1 Hz 50 0Hz 25H H1 09 PULSE maxi Input pulse 0 1 20 0K 0 1K 10 0K 26H H1 10 Mini PULSE rated...

Страница 9: ...rewquaency compensation 0 150 0 no slip frewquaency compensation 1 0 37H H3 04 Jog operating frequency 0 1 50 0Hz 0 1Hz 5 0Hz 38H H3 05 Jog ACCE time 0 1 60 0s 0 1s 20 0s 39H H3 06 Jog DCCE time 0 1 6...

Страница 10: ...ency Upper limit frequency 0 01Hz 20 0Hz 49H H3 22 Multi frequency 4 Lower limit frequency Upper limit frequency 0 01Hz 30 0Hz 4AH H3 23 Multi frequency 5 Lower limit frequency Upper limit frequency 0...

Страница 11: ...ing time unit 0 second 1 minute 1 000 59H H4 H4 H4 H4 Simple PLC Function Parameters Simple PLC Function Parameters Simple PLC Function Parameters Simple PLC Function Parameters H4 01 Pahse 1 setting...

Страница 12: ...CI analog input 1 1 6AH H5 03 Digital setting of given quantity 0 00 10 00V 0 01 0 00 6BH H5 04 Mini Given quantity 0 0 maxi given quantity relative to percentage of 10 00V 0 1 0 0 6CH H5 05 Mini Give...

Страница 13: ...trol 20 closed loop invalid 21 PLC invalid 22 simple PLC suspension operation control 23 PLC reset when in stop status 24 frequency given channel selection1 25 frequency given channel selection 2 26 f...

Страница 14: ...nter reaches the rated value 19 reaches the set operating time 20 inner timer arrives 1 0 86H H6 12 Fault radiator RA RB RC function selection 0 Inverter is in operating RUN 1 frequency arriving signa...

Страница 15: ...ches given value 0 9999 1 0 95H H6 26 Inner timer timing setting 0 1 6000 0s 0 1 60 0 96H H7 H7 H7 H7 Specific Traverse Function Parameters Specific Traverse Function Parameters Specific Traverse Func...

Страница 16: ...de VF curve 1 0 3200 0Hz 0 01Hz Accordi ng to machine type A2H H8 04 Motor rated speed 1 9999r min 1r min Accordi ng to machine type A3H H8 05 Motor pole number 2 14 2 Accordi ng to machine type A4H H...

Страница 17: ...ion value 0 0 100 0 0 1 0 0 BDH HA 01 Feedback disconnection dealy time 0 0 999 9s 0 1 0 0 BEH HA 02 Remote pressure gauge range 0 00 20 00Mpa 0 01 1 00 BFH HA 03 Sleeping frequency 0 0 99 9Hz 0 1 0 0...

Страница 18: ...al Parameters Secret Code and Manufacturer Functional Parameters Secret Code and Manufacturer Functional Parameters Secret Code and Manufacturer Functional Parameters HE 00 User code 0000 9999 1 0000...

Страница 19: ...ault type ault type P P P Paossible reasons aossible reasons aossible reasons aossible reasons C C C Count ount ount ountermeasures ermeasures ermeasures ermeasures Inverter instantaneous overcurrent...

Страница 20: ...e properly U 05 Inverter accelerate the operating speed and overvoltage Restart the rotating motor Set it as detection restarting function Decceleration time is too short Extend the DCCE time U 06 Inv...

Страница 21: ...d Check the load U 12 Reserved Reserved Reserved U 13 Reserved Reserved Reserved Duct obstrution Clear the duct or improve ventilation The environment tempreture is too high Improve the ventilation lo...

Страница 22: ...es agent for assist U 23 Reserved Reserved Reserved U 25 Disconnection of PID feedback Disconnection of PID feedback Check the feedback wiring PoFF Undervoltage when stop Abnormal input voltage Check...

Страница 23: ...t five times Hd 10 DC bus voltage when the fault happened last time Hd 05 Fault record for the last six times 3 3 Fault Reset 3 3 Fault Reset 3 3 Fault Reset 3 3 Fault Reset When faults happens you ca...

Отзывы: