![K&G GROEP NANO MARINE Скачать руководство пользователя страница 2](http://html2.mh-extra.com/html/kandg-groep/nano-marine/nano-marine_installation-and-operation-manual_3057869002.webp)
Design Installation Operation Manual NANO/MAR/SYSTEM January 1, 2023 | version 1.2 P
2
TABLE OF CONTENTS
1
DOCUMENT REVISION DETAILS
3
2
SOFTWARE UPGRADE DETAILS
3
3
ABBREVIATIONS
3
4
IMPORTANT NOTES
3
5
CERTIFICATION
3
6
INTRODUCTION
4
7
ENCLOSURE & INSTALLATION
4
8
MAINTENANCE & CLEANING
4
9
NANO MARINE SYSTEM
5
10
KEY PROPERTIES
6
11
FEATURES NANO/MAR/SYSTEM
6
11.1 A
COUSTIC ALARM
6
11.2 E
XTINGUISHANT RELEASE OUTPUT
6
11.3 H
ISTORIC EVENT LOG
7
11.4 C
OMMUNICATION PORT
7
11.5 D
IRECT RELEASE
7
11.6 V
EHICLE MODE
(
NORMALLY NOT IN USE IN MARINE APPLICATIONS
)
7
11.7 G
ENERAL FAULT RELAY
7
11.8 VFC
FIRE RELAY IN SINGLE OF DUAL MODE
8
11.9 S
INGLE OR DUAL ZONE
8
11.10 E
XTINGUISHANT RELEASE DELAY
8
12
INPUTS
8
12.1 D
ETECTION ZONES
8
12.2 E
XTERNAL RELEASE INPUT
9
12.3 E
XTERNAL HOLD INPUT
9
13
OUTPUTS
9
13.1 V
OLT
F
REE
C
ONTACT RELAY OUTPUTS
9
13.2 M
ONITORED EXTINGUISHING OUTPUT
9
13.3 M
ONITORED SOUNDER OUTPUT
9
14
CONTROL BUTTONS
10
14.1 M
UTE
10
14.2 R
ESET
10
14.3 L
AMP TEST
10
14.4 H
OLD EXTINGUISHING RELEASE
10
14.5 A
UTOMATIC
&
MANUAL RELEASE OR MANUAL ONLY MODE
10
14.6 E
XTINGUISHING RELEASE
10
15
LED INDICATORS
11
15.1
M
ANUAL RELEASE ONLY
11
15.2
A
UTOMATIC
&
MANUAL RELEASE
11
15.3 P
OWER
(PSU
1
IS MAINS
PSU
2
IS BACKUP
)
11
15.4 C
OMMON FIRE
11
15.5 F
IRE ZONE ALARM
12
15.6 E
XTINGUISHING RELEASED
12
15.7 E
XTINGUISHING DELAY
12
15.8 G
ENERAL FAULT
12
15.9 F
IRE ZONE FAULT
12
15.10 E
XTINGUISHING RELEASE HOLD
12
15.11 E
XTINGUISHING RELEASE FAULT
12
15.12
I
NTERNAL FAULT INDICATORS
12
16
DIP SWITCHES
13
16.1 S
ETTINGS
13
16.2 D
IRECT RELEASE
(PDS
1)
13
16.3 V
EHICLE MODE
(PDS
2)
13
16.4 E
XTINGUISHING RELEASE OUTPUT
(PDS
3)
13
16.5 S
INGLE OR DUAL FIRE ALARM
(PDS
4)
14
16.6 VFC
RELAY
(PDS
5)
14
16.7 E
XTINGUISHING DELAY TIMER
(PDS
6-7-8)
14
17
WIRING THE NCP AND NETB
15
18
WIRING DIAGRAM NETB 5
16
19
WIRING DIAGRAM NETB 10
17
20
CONNECTING USING THE EXTINGUISHER TERMINAL BOX (NETB)
18
21
EXAMPLE SWITCH POSITION NETB 5 WITH 3 EXTINGUISHERS
18
22
EXAMPLE SWITCH POSITION NETB 10 WITH 7 EXTINGUISHERS
19
23
THE NMS USING A SOLENOID ACTIVATOR
19
23.1 W
IRING A SOLENOID ACTIVATION SYSTEM
20
24
WIRING & CABLE SPECIFICATIONS:
20
25
TECHNICAL SPECIFICATION
21
26
DEVICES SUPPORTED BY THE NMS
22
26.1
DETECTION DEVICE SUPPORT
22
26.2
SOUNDER
/
BEACON DEVICE SUPPORT
22
27
ENCLOSURE SPECIFICATIONS NCP
22
28
NMS FIRE DETECTOR AND WIRING OPTIONS
23
29
EXTERNAL EXTINGUISHERS RELEASE & HOLD WIRING OPTIONS
24
30
VTB-EM WIRING OPTION SOUNDER & BEACON
24
31
VTB-EM WIRING OPTION EXTENDED SOUNDER & BEACONS
25
32
WARRANTY
26
33
NOTES
27