K&G GROEP NANO MARINE Скачать руководство пользователя страница 2

 

                              Design Installation Operation Manual  NANO/MAR/SYSTEM  January 1, 2023 | version 1.2  P

 

2

 

TABLE OF CONTENTS

 

DOCUMENT REVISION DETAILS 

SOFTWARE UPGRADE DETAILS 

ABBREVIATIONS 

IMPORTANT NOTES 

CERTIFICATION 

INTRODUCTION 

ENCLOSURE & INSTALLATION 

MAINTENANCE & CLEANING 

NANO MARINE SYSTEM 

10 

KEY PROPERTIES 

11 

FEATURES NANO/MAR/SYSTEM 

11.1  A

COUSTIC ALARM

 

11.2  E

XTINGUISHANT RELEASE OUTPUT

 

11.3  H

ISTORIC EVENT LOG

 

11.4  C

OMMUNICATION PORT

 

11.5  D

IRECT RELEASE

 

11.6  V

EHICLE MODE 

(

NORMALLY NOT IN USE IN MARINE APPLICATIONS

11.7  G

ENERAL FAULT RELAY

 

11.8  VFC

 FIRE RELAY IN SINGLE OF DUAL MODE

 

11.9  S

INGLE OR DUAL ZONE

 

11.10  E

XTINGUISHANT RELEASE DELAY

 

12 

INPUTS   

12.1  D

ETECTION ZONES

 

12.2  E

XTERNAL RELEASE INPUT

 

12.3  E

XTERNAL HOLD INPUT

 

13 

OUTPUTS 

13.1  V

OLT 

F

REE 

C

ONTACT RELAY OUTPUTS

 

13.2  M

ONITORED EXTINGUISHING OUTPUT

 

13.3  M

ONITORED SOUNDER OUTPUT

 

14 

CONTROL BUTTONS 

10 

14.1  M

UTE

 

 

10 

14.2  R

ESET

 

 

10 

14.3  L

AMP TEST

 

10 

14.4  H

OLD EXTINGUISHING RELEASE

 

10 

14.5  A

UTOMATIC 

&

 MANUAL RELEASE OR MANUAL ONLY MODE

 

10 

14.6  E

XTINGUISHING RELEASE

 

10 

15 

LED INDICATORS 

11 

15.1

  M

ANUAL RELEASE ONLY

 

11 

15.2

  A

UTOMATIC 

&

 MANUAL RELEASE

 

11 

15.3  P

OWER 

(PSU

 

1

 IS MAINS 

PSU

 

2

 IS BACKUP

11 

15.4  C

OMMON FIRE

 

11 

15.5  F

IRE ZONE ALARM

 

12 

15.6  E

XTINGUISHING RELEASED

 

12 

15.7  E

XTINGUISHING DELAY

 

12 

15.8  G

ENERAL FAULT

 

12 

15.9  F

IRE ZONE FAULT

 

12 

15.10  E

XTINGUISHING RELEASE HOLD

 

12 

15.11  E

XTINGUISHING RELEASE FAULT

 

12 

15.12 

 

I

NTERNAL FAULT INDICATORS

 

12 

16 

DIP SWITCHES 

13 

16.1  S

ETTINGS

  

13 

16.2  D

IRECT RELEASE 

(PDS

 

1) 

13 

16.3  V

EHICLE MODE 

(PDS

 

2) 

13 

16.4  E

XTINGUISHING RELEASE OUTPUT 

(PDS

 

3) 

13 

16.5  S

INGLE OR DUAL FIRE ALARM 

(PDS

 

4) 

14 

16.6  VFC

 RELAY 

(PDS

 

5) 

14 

16.7  E

XTINGUISHING DELAY TIMER 

(PDS

 

6-7-8) 

14 

17 

WIRING THE NCP AND NETB 

15 

18 

WIRING DIAGRAM NETB 5 

16 

19 

WIRING DIAGRAM NETB 10 

17 

20 

CONNECTING USING THE EXTINGUISHER TERMINAL BOX (NETB) 

18 

21 

EXAMPLE SWITCH POSITION NETB  5 WITH 3 EXTINGUISHERS 

18 

22 

EXAMPLE SWITCH POSITION NETB  10 WITH 7 EXTINGUISHERS 

19 

23 

THE NMS USING A SOLENOID ACTIVATOR 

19 

23.1  W

IRING A SOLENOID ACTIVATION SYSTEM

 

20 

24 

WIRING & CABLE SPECIFICATIONS: 

20 

25 

TECHNICAL SPECIFICATION 

21 

26 

DEVICES SUPPORTED BY THE NMS 

22 

26.1 

DETECTION DEVICE SUPPORT

 

22 

26.2 

SOUNDER 

/

 BEACON DEVICE SUPPORT

 

22 

27 

ENCLOSURE SPECIFICATIONS NCP 

22 

28 

NMS FIRE DETECTOR AND WIRING OPTIONS 

23 

29 

EXTERNAL EXTINGUISHERS RELEASE & HOLD WIRING OPTIONS 

24 

30 

VTB-EM WIRING OPTION SOUNDER & BEACON 

24 

31 

VTB-EM WIRING OPTION EXTENDED SOUNDER & BEACONS 

25 

32 

WARRANTY 

26 

33 

NOTES   

27

 

Содержание NANO MARINE

Страница 1: ...www kg groep com January 1 2023 version 1 2 Design Installation Operation Manual NANO MARINE FIRE DETECTION EXTINGUISHING CONTROL SYSTEM...

Страница 2: ...TOMATIC MANUAL RELEASE 11 15 3 POWER PSU 1 IS MAINS PSU 2 IS BACKUP 11 15 4 COMMON FIRE 11 15 5 FIRE ZONE ALARM 12 15 6 EXTINGUISHING RELEASED 12 15 7 EXTINGUISHING DELAY 12 15 8 GENERAL FAULT 12 15 9...

Страница 3: ...rd to any relevant information or advice relating to its use that has been made available by the supplier The NMS and the associated connections must be installed commissioned and maintained by a skil...

Страница 4: ...lled in an accessible area Take into consideration environmental factors such as high temperatures The enclosure is provided of 7 predrilled holes for cable glands To ensure IP rating the cables must...

Страница 5: ...ress both yellow extinguishing release pushbuttons this will trigger an alarm on the NCP The fire extinguishers will be released depending on the PDS time settings The cable connection between the NCP...

Страница 6: ...rked DNV CG type approval according the 0339 DNV CG standard 11 FEATURES NANO MAR SYSTEM 11 1ACOUSTIC ALARM The NCP has an internal attention signal Malfunctions are standard signalized with a continu...

Страница 7: ...lay immediately This function can be selected via PDS 1 11 6VEHICLE MODE NORMALLY NOT IN USE IN MARINE APPLICATIONS If the extinguishing system is intended for the protection of a vehicle engine bay t...

Страница 8: ...er is used to wait a certain amount of time before extinguisher s are activated 12 INPUTS The NCP is equipped with two detection zones and two external button inputs Extinguishing Release Hold These i...

Страница 9: ...e electronic sounder beacon output 13 1VOLT FREE CONTACT RELAY OUTPUTS Contact load relays 30 VDC 1A 1 relay output general fire alarm The general fire relay will energize upon activation of a fire co...

Страница 10: ...he hold button at the panel or external hold button as long this button is pressed the extinguishing release sequence will be halted and cause the yellow hold activated indicator flash and the buzzer...

Страница 11: ...disconnection of the backup power will cause a fault The power LED lite differently indicating an abnormality in the power supply to the NCP When starting the NMS after a power failure or an extinguis...

Страница 12: ...ay time has elapsed and the extinguishing release has taken place 15 8GENERAL FAULT General fault indicator lights and specific fault indicators flash This yellow fault indicator will light continuous...

Страница 13: ...ay has been programmed PDS 1 ON extinguishing without delay in manual operation 16 3VEHICLE MODE PDS 2 If the extinguishing system is intended to protect the engine compartment of a vehicle a programm...

Страница 14: ...relay active with 1st fire alarm 16 7EXTINGUISHING DELAY TIMER PDS 6 7 8 Extinguishing delay is only useful in normally occupied spaces For the delay timer settings there are 3 PDS which can be set b...

Страница 15: ...ne 2 Fire detector Fire detector Fire detector Fire detector common fire general fault 1 st or 2 nd stage fire vehicle mode Event log usb connection RS 485 A RS 485 B RS 485 0 battery battery main pow...

Страница 16: ...Design Installation Operation Manual NANO MAR SYSTEM January 1 2023 version 1 2 P 16 18 WIRING DIAGRAM NETB 5...

Страница 17: ...www kg groep com P 17 19 WIRING DIAGRAM NETB 10...

Страница 18: ...ng and maintenance engineers work This visual inspection must be a standard provision in the commissioning regulation 21 EXAMPLE SWITCH POSITION NETB 5 WITH 3 EXTINGUISHERS DISCONNECT EXTINGHUISHER Mo...

Страница 19: ...n addition to a fire extinguishing output for electric igniters meant for aerosol fire extinguishing generators the NCP also has an extinguishing output suitable for a solenoid controlled fire extingu...

Страница 20: ...tch in the extinguishing output line to perform test and maintenance work without activating the extinguishing system 24 WIRING CABLE SPECIFICATIONS There is NO need for shielded cable Use a pair twis...

Страница 21: ...e Cross Sectional Area mm 0 5 mm 1 5 mm Conductor cross section AWG 20 16 Stripping length 8 mm Aerosol extinguisher output specification Maximum Stat X extinguisher count 5 connected on NETB 5 max 12...

Страница 22: ...4 MAR heat 73 C detector Apollo ORB HT 41006 MAR heat 90 C detector Apollo ORB MB 00001 MAR standard detector base Apollo 26 2SOUNDER BEACON DEVICE SUPPORT Part no Type Brand VTB 32EM DB RB RL VTB sou...

Страница 23: ...groep com P 23 28 NMS FIRE DETECTOR AND WIRING OPTIONS There are three options for connecting fire detectors to the NCP Conventional Apollo Orbis MAR fire detectors Heat detectors Linear cable heat de...

Страница 24: ...M WIRING OPTION SOUNDER BEACON By a single sounder beacon follow the connection diagram below The recommended setting gives the best and deviating alarm signal compared to the usual evacuation alarm s...

Страница 25: ...han a single sounder beacon follow the connection diagram below The recommended setting gives the best and deviating alarm signal compared to the usual evacuation alarm signal on vessels Recommended s...

Страница 26: ...ut not limited to damage or loss of property or equipment cost of de installation or reinstallation cost of transport or storage loss of profits or revenue cost of capital cost of purchased or replace...

Страница 27: ...her electronically mechanically or by photocopying recording or in any other way without prior written permission from K G GROEP B V The policy of the K G GROEP B V is one of continuous improvement an...

Отзывы: